Purpose: Low-magnitude, high-frequency(LMHF) loading has been confirmed to play an important role in bone healing. The present study aimed to evaluate the effect of LMHF loading applied directly to titanium dental implants on peri-implant bone healing and implant.
Methods: The mandibular premolars and molars were extracted from six male Beagle dogs. Three months post-extraction, six titanium implants (Aadva Standard Implant Narrow, 3.3 mm×8 mm) were inserted into the mandibular premolar and molar area (three implants per side) in each of the six dogs. In each animal, one side was randomly selected to undergo daily LMHF loading (experimental group), while the other side had no further intervention (control group). The loading was applied directly to the implant abutment using an individual jig and a custom-made loading device (8 μm,100 Hz). The implant stability quotient (ISQ) was tested every week. Three dogs were euthanized after 2 weeks, and three were euthanized after 8 weeks. Tissue samples were fixed and stained for micro-computed tomography(micro-CT) and histomorphometric analyses. The data were statistically analyzed using SPSS 13.0 software package.
Results: The experimental group had significantly increased peri-implant bone volume relative to tissue volume in region of interest 2 (100-500 μm) compared with the control group after 2 weeks of loading (P<0.05); however, there was no significant difference between the two groups after 8 weeks (P>0.05). The ISQ value and the micro-CT results did not differ between the two groups during the study period.
Conclusions: LMHF loading positively influences peri-implant bone healing and osseointegration in the early healing period.
Download full-text PDF |
Source |
---|
BMC Oral Health
January 2025
Department of Prosthetic Dentistry, Biomaterials Division, Faculty of Dentistry, King Salman International University, El Tur, South Sinai, Egypt.
Purpose: Investigating high performance thermoplastic polymers as substitutes to titanium alloy, in fabrication of implants and attachments to support mandibular overdenture, aiming to overcome stress shielding effect of titanium alloy implants. AIM OF STUDY: Assessment of stress distribution in polymeric prosthetic components and bone around polymeric implants, in case of implant-supported mandibular overdenture.
Materials And Methods: 3D finite element model was established for mandibular overdenture, supported bilaterally by two implants at canine region, and retained by two ball attachments.
Heliyon
January 2025
Stomatology Medical Center, Aviation General Hospital, Beijing, China.
Objective: This observational study investigated the relationship between occlusal balance and the tightness of restorative-contralateral occlusal contact in patients undergoing dental implant restorations.
Methods: A total of 100 patients who received dental implant restorations at our hospital between July 2022 and July 2023 were included. Patients were divided into two groups based on occlusal closeness: an observation group (using 12 μm occlusal paper for occlusion) and a control group (using 20 μm occlusal paper for occlusion).
J Nanobiotechnology
January 2025
Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, No.639 Zhizaoju Road, Shanghai, 200011, China.
Studies have shown that the prognosis of dental implant treatment in patients with diabetes is not as good as that in the non-diabetes population. The nerve plays a crucial role in bone metabolism, but the role and the mechanism of peripheral nerves in regulating peri-implant osteogenesis under Type 2 diabetes mellitus (T2DM) situation remains unclear. In this study, it was shown that high glucose-stimulated Schwann cells (SCs) inhibited peri-implant osteogenesis via their exosomes.
View Article and Find Full Text PDFJ Contemp Dent Pract
October 2024
Department of Crown and Bridge, Faculty of Dentistry, Al-Azhar University, Cairo, Egypt.
Aim: To assess hard as well as soft peri-implant tissues within cases having two lost adjacent anterior teeth treated through placing either two implants with two separate crowns or only an implant along with a crown with a cantilever, and evaluating the effect of polyetheretherketone (PEEK) restoration on cantilever design up to 18 months after functional loading.
Materials And Methods: Twenty-seven participants (15 males and 12 females; mean age, 38.6 years; range 20-50 years) with missing two adjacent anterior teeth were treated with implant system (Flotecno implant system, Italy).
J Prosthodont
January 2025
Division of Oral Surgery and Implantology, Department of Head and Neck, Institute of Clinical Dentistry, Oral Surgery and Implantology Unit, A. Gemelli University Hospital Foundation (IRCCS) Catholic University of the Sacred Heart, Rome, Italy.
Purpose: Screw-retained implant crowns are a common solution to rehabilitate single or multiple edentulous sites. Angulated screw channel (ASC) abutments have been developed as a new system of connection to correct the angulation of the implant and avoid a possible undesired emergence of the access hole. The purpose of this systematic review was to examine available literature related to the effects of ASC abutments in rehabilitating single implant crowns.