An assay to detect carbon monoxide (CO), one of the gaseous signaling molecules, has been prepared using a new palladium complex probe. The ethylenediamine group linked to the naphthalimide fluorophore coordinates to Pd(II) which intramolecularly quenches the emission. Upon treatment with CO, the absorbance of the turn-on fluorescent sensor changes due to the formation of a complex between Pd(II) and CO at room temperature in a phosphate buffer. As the concentration of CO increases, the probe peak emission intensity at 527 nm gradually increases. Other analyte controls, such as K, Mg, Al, Zn, Cr, Hg, Fe, alanine, glycine, leucine, lysine, serine, threonine, tyrosine, F, Cl, Br, NO, NO, NO, HCO, CHCOO, HO, OH, and BuOO, exhibit no significant effect on emission intensity. The response time of the probe to CO was quite fast because of the relatively weak coordination of Pd(II) to the pendent ethylenediamine group. The Pd probe is capable of detecting CO in aqueous buffer as well as in living cells with high selectivity and stability, providing a potential real-time indicator for studying CO-involved reactions in biological systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.inorgchem.1c00091 | DOI Listing |
Med Sci Monit
January 2025
Department of Endodontics, Faculty of Dentistry, Dicle University, Diyarbakir, Turkey.
BACKGROUND Different temperature conditions can affect the efficiency of irrigation solutions and consequently the ability of canal sealers to bond to root canal walls. The aim of this endodontic study was to evaluate the effect of irrigation solutions at different temperatures on the bond strength of a bioceramic-based root canal sealer. MATERIAL AND METHODS Root canal preparations were completed through irrigation with the following solutions: Group 1 was irrigated with 5 ml NaOCl (sodium hypochlorite) +5 ml EDTA (Ethylenediamine tetra-acetic acid) (22°C); Group 2 was irrigated with 5 ml NaOCl +5 ml EDTA (37°C); Group 3 was irrigated with 5 ml NaOCl +5 ml GA (Glycolic acid) (22°C); Group 4 was irrigated with 5 ml NaOCl +5 ml GA (37°C), Group 5 was irrigated with 20 ml Dual Rinse® HEDP (Etidronate) - NaOCl mixture (22°C); and Group 6 was irrigated with 20 ml of Dual Rinse® HEDP mixture (37°C).
View Article and Find Full Text PDFClin Oral Investig
January 2025
Department of Pedodontics, Faculty of Dentistry, Erciyes University, 38039, Kayseri, Türkiye.
Objectives: This study evaluates the effect of different irrigation solutions for postoperative pain in the regenerative endodontic treatments (RET) of necrotic teeth with open apex.
Materials And Methods: This study included necrotic, deeply carious lower molars of 42 patients. Access cavities of the teeth were opened and working lengths were measured at the first visit.
Angew Chem Int Ed Engl
January 2025
Nankai University, SKLEOC, 300071, Tianjin, CHINA.
Amino groups are abundant in both natural and synthetic molecules, offering highly accessible sites for modifying native biorelevant molecules. Despite significant progress with more reactive thiol groups, methods for connecting two amino groups with reversible linkers for bioconjugation applications remain elusive. Herein, we report the use of oxidative decarboxylative condensation of glyoxylic acid to crosslink two alkyl amines via a compact formamidine linkage, applicable in both intra- and intermolecular contexts.
View Article and Find Full Text PDFTransfusion
January 2025
Department of Blood Transfusion, Fujita Health University Hospital, Toyoake, Japan.
Background: Ethylenediamine tetraacetate/glycine acid (EGA) and chloroquine diphosphate (CDP) are used in transfusion testing to dissociate IgG antibodies from red blood cells (RBCs). However, the ability of these reagents to dissociate IgM antibodies sensitized to RBCs has not been comprehensively elucidated. We investigated whether EGA and CDP could dissociate cold-reactive antibodies from RBCs and their effect on RBCs after dissociation treatment.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Faculty of Dentistry, Basic Medical Sciences Department, Ankara University, Ankara, 06560, Turkey.
Background: This study aimed to comparatively evaluate the effects of different cavity conditioners on internal adaptation (IA) of glass ionomer-based restorative materials applied to primary teeth.
Methods: 80 extracted primary second molar teeth were randomly assigned to four different cavity conditioner groups [10% polyacrylic acid, 20% polyacrylic acid, 17% ethylene diamine tetraacetic acid (EDTA), 35% phosphoric acid]. Class V cavities were prepared on the buccal surfaces and relevant cavity conditioners were applied, and the samples in each cavity conditioner group were randomly assigned to glass hybrid (GHR) or conventional glass ionomer restoratives (CGIR).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!