A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrodeposition immobilized molybdenum disulfide quantum dots and their electrochemiluminescence application in the detection of melamine residues in milk powder. | LitMetric

Electrodeposition immobilized molybdenum disulfide quantum dots and their electrochemiluminescence application in the detection of melamine residues in milk powder.

Anal Methods

The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou 215123, P. R. China.

Published: May 2021

In this paper, one-step hydrothermal and electrodeposition methods were used to prepare a MoS2 quantum dot (QD) solid-phase electrochemiluminescent (ECL) electrode for the detection of melamine residues in milk powder. With the assistance of chitosan, MoS2 QDs fixed by the one-step electrodeposition method show better ECL performance than those by traditional deposition methods due to better dispersibility and stability. Based on the quenching of the MoS2 QDs ECL signal by melamine, quantitative detection of melamine in the sample was performed. The structure and morphology of a MoS2-CHIT/indium tin oxide (ITO) solid-phase ECL electrode were characterized by TEM and XPS, and melamine was detected by the ECL method using a three-electrode system. The proposed sensor exhibited good linearity in the range of 1.00 × 10-11 to 1.00 × 10-7 mol L-1 (ΔI = 12 100.62 + 1009.93 lg c (mol L-1), R2 = 0.997), and the method shows the advantages of simplicity and sensitivity compared to traditional detection methods. The interference of common ions in milk powder on the modified electrode was within 5%, and the recovery rate of real sample detection was within 97-98%. As a result, the proposed method is suitable for detecting melamine residues in milk powder.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d1ay00364jDOI Listing

Publication Analysis

Top Keywords

milk powder
16
detection melamine
12
melamine residues
12
residues milk
12
ecl electrode
8
mos2 qds
8
mol l-1
8
melamine
6
detection
5
ecl
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!