Precis: Visual field (VF) endpoints based on average deviation of specific subsets of points rather than all points may offer a more homogeneous data set without necessarily worsening test-retest variability and so may be useful in clinical trials.

Purpose: The purpose of this study was to characterize the outcome measures encompassing particular subsets of VF points and compare them as obtained with Humphrey [Humphrey visual field analyser (HVF)] and Compass perimeters.

Methods: Thirty patients with imaging-based glaucomatous neuropathy performed a pair of 24-2 tests with each of 2 perimeters. Nonweighted mean deviation (MD) was calculated for the whole field and separate vertical hemifields, and again after censoring of points with low sensitivity (MDc) and subsequently including only "abnormal" points with a total deviation probability of <5% (MDc5%) or <2% (MDc2%). Test-retest variability was assessed using Bland-Altman 95% limits of agreement (95%LoA).

Results: For the whole field, using HVF, MD was -7.5±6.9 dB, MDc -3.6±2.8 dB, MDc5% -6.4±1.7 dB, and MDc2% -7.3±1.5 dB. With Compass the MD was -7.5±6.6, MDc -2.9±1.7 dB, MDc5% -6.3±1.5, and MDC2% -7.9±1.6. The respective 95%LoA were 5.5, 5.3, 4.6, and 5.6 with HVF, and 4.8, 3.7, 7.1, and 7.1 with Compass. The respective number of eligible points were 52, 42±12, 20±11, and 15±9 with HVF, and 52, 41.2±12.6, 10±7, and 7±5 with Compass. With both machines, SD and 95%LoA increased in hemifields compared with the total field, but this increase was mitigated after censoring.

Conclusion: Restricting analysis to particular subsets of points of interest in the VF after censoring points with low sensitivity, as compared with using the familiar total field MD, can provide outcome measures with a broader range of MD, a markedly reduced SD and therefore more homogeneous data set, without necessarily worsening test-retest variability.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IJG.0000000000001856DOI Listing

Publication Analysis

Top Keywords

visual field
12
field endpoints
8
endpoints based
8
subsets points
8
points
6
based subgroups
4
subgroups points
4
points glaucoma
4
glaucoma clinical
4
clinical trials
4

Similar Publications

Dual Ratiometric Fluorescence Sensors Based on Chiral Carbon Dots for the Sensitive and Specific Detection of Arginine.

Anal Chem

January 2025

State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China.

Arginine (Arg) is involved in tissue metabolism and regulates the immune function; thereby, achieving the detection of Arg is crucial for early diagnosis and treatment of diseases. Herein, dual ratiometric fluorescence sensors were prepared with the blue emission of levorotatory/dextrorotatory carbon dots (CDs) and the red emission of porphyrin (L/D-CDs-PP) for the sensitive and portable detection of Arg. Interestingly, L-CDs-PP and D-CDs-PP displayed not only the dual emission peaks at 493 and 650 nm but also different response modes to Arg; thus, they could serve as dual ratiometric fluorescence sensors to achieve the accurate and reliable detection of Arg, with the detection limit of 23.

View Article and Find Full Text PDF

Background: The vascular endothelial growth factor (VEGF) signaling pathway is closely related to pathological angiogenesis in liver disease. Anti-angiogenesis is an effective intervention in the clinical treatment of liver disease. Some antiangiogenic drugs are resistant and have limitations in clinical use.

View Article and Find Full Text PDF

Longitudinal Assessment of Structural and Functional Changes in Rod-cone Dystrophy: A 10-year Follow-up Study.

Ophthalmol Sci

November 2024

Faculty of Medicine, Dentistry and Health Sciences, Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Australia.

Purpose: Emerging clinical trials for inherited retinal disease (IRD) require an understanding of long-term progression. This longitudinal study investigated the genetic diagnosis and change in retinal structure and function over 10 years in rod-cone dystrophies (RCDs).

Design: Longitudinal observational follow-up study.

View Article and Find Full Text PDF

Purpose: To describe progression of best-corrected visual acuity (BCVA), full-field stimulus thresholds (FST), and electroretinography (ERG) over 4 years in the -related Retinal Degeneration study and to assess their suitability as clinical trial endpoints.

Design: Prospective natural history study.

Participants: Participants (n = 105) with biallelic disease-causing sequence variants in USH2A and BCVA letter scores of ≥54 were included.

View Article and Find Full Text PDF

African mole-rats (Bathyergidae, Rodentia) are subterranean rodents that live in extensive dark underground tunnel systems and rarely emerge aboveground. They can discriminate between light and dark but show no overt visually driven behaviours except for light-avoidance responses. Their eyes and central visual system are strongly reduced but not degenerated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!