A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy. | LitMetric

Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy.

Natl J Maxillofac Surg

Department of Oral and Maxillofacial Surgery, Saifee Hospital, Mumbai, Maharashtra, India.

Published: December 2020

Dental implants have been in vogue for more than three decades as a successful mode of rehabilitation of lost dentition. With time, there have been updates in methods and science including a positive tilt toward incorporation of digital technology into treatment protocols. This report elucidates a rare case of faulty osteotomy preparation through a computer-aided design computer-aided manufacturing stent that was detected and corrected before implant placement. The manuscript also emphasizes the possible shrinkage of soft-tissue graft beyond the normal postulated time frame and the importance of periodical checks on the drilling protocol throughout the flapless placement procedure even though it may have been seamlessly planned on the digital platform.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8051656PMC
http://dx.doi.org/10.4103/njms.NJMS_51_20DOI Listing

Publication Analysis

Top Keywords

computer-aided design
8
design computer-aided
8
computer-aided manufacturing
8
dimensional changes
4
changes soft
4
soft tissue
4
tissue plausible
4
plausible error
4
computer-aided
4
error computer-aided
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!