Assessment of pedicle size in patients with scoliosis using EOS 2D imaging: a validity and reliability study.

Eur Spine J

Department of Orthopaedics, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.

Published: December 2021

Purpose: Free-hand pedicle screw insertion methods are widely used for screw insertion during scoliosis surgery. Preoperative knowledge about the pedicle size helps to maximize screw containment and minimize the risk of pedicle breach. Radiographs taken by a biplanar low-dose X-ray device (EOS) have no divergence in the vertical plane. The criterion validity and reliability of preoperative EOS images for pedicle size measurements in patients with idiopathic scoliosis (IS) was investigated in this study.

Methods: Sixteen patients who underwent surgical treatment for IS were prospectively included. Intra- and extracortical pedicle height and width measurements on EOS images were compared with reconstructed intra-operative 3D images of the isthmus of included pedicles. Secondly, intra- and interobserver reliability of pedicle size measurements on EOS images was determined.

Results: The total number of analyzed pedicles was 203. The correlation between the EOS and 3D scan measurements was very strong for the intra- and extracortical pedicle height and strong for the intra- and extracortical pedicle width. There are, however, significant, but likely clinically irrelevant differences (mean absolute differences < 0.43 mm) between the two measure methods for all four measurements except for extracortical pedicle height. For pedicles classified as Nash-Moe 0, no significant differences in intra- and extracortical pedicle width were observed. Both intra- and interobserver reliability was excellent for all pedicle size measurements on EOS images.

Conclusion: The results of this study indicate a good validity and reliability for pedicle size measurements on EOS radiographs. Therefore, EOS radiographs may be used for a preoperative estimation of pedicle size and subsequent screw diameter in patients with IS.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00586-021-06839-8DOI Listing

Publication Analysis

Top Keywords

pedicle size
16
eos images
12
intra- extracortical
12
extracortical pedicle
12
validity reliability
8
pedicle
8
screw insertion
8
size measurements
8
pedicle height
8
measurements eos
8

Similar Publications

Background: With the rising diagnostic rate of gallbladder polypoid lesions (GPLs), differentiating benign cholesterol polyps from gallbladder adenomas with a higher preoperative malignancy risk is crucial. This study aimed to establish a preoperative prediction model capable of accurately distinguishing between gallbladder adenomas and cholesterol polyps using machine learning algorithms.

Materials And Methods: We retrospectively analysed the patients' clinical baseline data, serological indicators, and ultrasound imaging data.

View Article and Find Full Text PDF

Background: Hepatocellular carcinoma (HCC) associated with major vasculature tumor extension is considered an advanced stage of disease to which palliative radiotherapy or chemotherapy is proposed. Surgical resection associated with chemotherapy or chemoembolization could be an opportunity to improve overall survival and recurrence-free survival in selected cases in a high-volume hepatobiliary center. Moreover, it has been 25 years since Couinaud described the entity of a posterior liver located behind an axial plane crossing the portal bifurcation.

View Article and Find Full Text PDF

Introduction: Necrotising soft tissue infection (NSTI) is an exceptionally dangerous infectious disease targeting soft tissues with high mortality as well as morbidity. The aim of reconstructive surgery after initial debridement is to maintain function as well as to achieve a satisfactory cosmetic result.

Presentation Of Case: A 50-year-old male presented with necrotising soft tissue infection on the thorax and left upper arm following mastectomy for breast cancer.

View Article and Find Full Text PDF

Surgery for chronic pyothorax after failed amplatzer closure of bronchopleural fistula.

J Cardiothorac Surg

January 2025

Department of Thoracic and Vascular Surgery, and Lung Transplantation, Marie-Lannelongue Hospital, Le Plessis-Robinson, France.

Background: Post-pneumonectomy bronchopleural fistula (BPF) is a life-threatening event whose treatment is not standardized.

Case Presentation: We report the management of a 28-year-old patient with a 3-year history of BPF complicating right pneumonectomy for congenital emphysema. Despite closure by an Amplatzer device, the patient had chronic pyothorax and severely deteriorated general health and quality of life.

View Article and Find Full Text PDF

The tumor distance to the main hepatic vessels is a predictor of recurrence-free survival and overall survival in hepatocellular cancer.

Langenbecks Arch Surg

January 2025

Department of Surgery, Medical Faculty Mannheim, Universitätsmedizin Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.

Introduction: The impact of the distance of the tumor from the main hepatic vessels (DTV), such as the Glissonean pedicle or hepatic veins, on oncological outcomes for Hepatocellular carcinoma (HCC) patients is relatively understudied. Therefore, the objective of this study was to explore the correlation between DTV and survival in patients with HCC after curative hepatic resection.

Methods: Consecutive patients who underwent curative-intent liver surgery for HCC between April 2018 and May 2023 were identified from a prospective database.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!