A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Technical Note: ID-card-size dosimeter based on radiochromic films for continuous personnel monitoring. | LitMetric

Purpose: This paper is aimed at investigating the feasibility of developing a personal dosimeter of cumulative radiation dose which would incorporate the following features: 1) a small size compared to that of a proximity ID card; 2) instant dose readout; 3) no power source; 4) moderate cost. The dosimeter is proposed as a potential replacement for TLD and OSL dosimeters used by nuclear industry workers and some medical staff groups.

Methods: An original detector design is developed containing a two-color LED, two photodetectors located in one plane covered with a mirror coating. The power necessary for the operation comes from an RFID reader. A small (5x5 mm) piece of Gafchromic EBT3 photochromic film sensitive to both X-ray and gamma radiation is used as a sensor. Irradiation of samples under X-ray and gamma radiation is carried out in the dose range of 0.1 cGy-1 Gy. The transmittance spectra are measured in the 300 nm-1100 nm spectral range.

Results: Several prototypes of the dosimeter are presented, the distinctive features of which are the absence of the power source, easy transmitting of the dosimetric data via a RF channel, and a slim form factor. Several sources of dose uncertainties are analyzed and ways to eliminate them are outlined. The average dose confidence interval (α = 0.05) calculated from the response curve is shown to equal 0.02 cGy. This makes it possible to reliably measure doses as low as 0.1 cGy, which corresponds to the minimum value claimed for Gafchromic EBT3.

Conclusions: The proposed idea of an ID-card-size dosimeter is feasible and has a number of advantages over TLD and OSL dosimeters, in particular, instant reading of the dose data using RFID/NFC readers, and a possibility of integrating into ERP systems.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.14893DOI Listing

Publication Analysis

Top Keywords

id-card-size dosimeter
8
power source
8
tld osl
8
osl dosimeters
8
x-ray gamma
8
gamma radiation
8
dose
6
dosimeter
5
technical note
4
note id-card-size
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!