A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid, quantitative, and high-sensitivity detection of anti-phospholipase A2 receptor antibodies using a novel CdSe/ZnS-based fluorescence immunosorbent assay. | LitMetric

Autoantibodies against M-type phospholipase A2 receptor (PLA2R) serve as specific biomarkers for idiopathic membranous nephropathy (IMN), and its quantification helps monitor disease activity. In this study, we describe a rapid and highly sensitive quantum dots-based immunochromatography assay (QD-ICA) for quantifying PLA2R autoantibodies. Serum samples from 135 biopsy-confirmed patients with nephrotic syndrome were analyzed for PLA2R autoantibodies using the novel QD-ICA as well as commercialized enzyme-linked immunosorbent assay (ELISA). Areas under the receiver operating characteristic curve (AUC-ROC) of QD-ICA were significantly greater than those of ELISA (91.1% [95% CI 85.9-96.3%] and 83.9% [95% CI 76.5-91.2%] respectively; p < 0.01). The detection sensitivity and specificity of QD-ICA (80.9% [95% CI 69.2-89.0%] and 100% [95% CI 93.2-100.0%], respectively) exceeded those of ELISA (72.1% [95% CI 59.7-81.9%] and 98.5% [95% CI 90.9-100.0%], respectively). The optimum cut-off value of QD-ICA was 18.18 relative units (RU)/mL, and the limit of detection was 2.86 RU/mL. The novel QD-ICA outperforms ELISA in detecting PLA2R autoantibodies, with shorter detection time, fewer steps, smaller equipment size, and broader testing application, suggesting its capability to improve IMN diagnosis and monitor patient response to treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8062494PMC
http://dx.doi.org/10.1038/s41598-021-88343-zDOI Listing

Publication Analysis

Top Keywords

immunosorbent assay
8
pla2r autoantibodies
8
rapid quantitative
4
quantitative high-sensitivity
4
high-sensitivity detection
4
detection anti-phospholipase
4
anti-phospholipase receptor
4
receptor antibodies
4
antibodies novel
4
novel cdse/zns-based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!