Background: Intravoxel incoherent motion imaging (IVIM) can non-invasively evaluate diffusion and microvascular perfusion.

Purpose: To explore the myocardium microcirculation of a healthy Chinese population by using cardiac magnetic resonance (CMR) IVIM.

Material And Methods: A total of 80 healthy volunteers (44 men, 36 women) who underwent 3.0-T CMR examination were enrolled. All participants had cardiac cine imaging and short-axis CMR-IVIM of the left ventricle (LV) using multiple b-values. The consistency of the IVIM parameters was assessed by intraclass correlation coefficient (ICC) and the Bland-Altman test. Spearman correlation analysis was performed between IVIM parameters and age, and body mass index (BMI). The differences of IVIM parameters were analyzed between gender and different ages.

Results: LV end-diastolic volume (EDV), end-systolic volume (ESV), LVmass, cardiac output (CO), and BMI in the male group were higher than those in the female group (<0.05). IVIM parameters had good intra-observer and inter-observer consistency (≥0.75). Bland-Altman analysis also showed good intra-observer and inter-observer consistency. ADC decreased with increasing female age (rs = -0.37;  = 0.01), while IVIM parameters had no correlation with BMI regardless of sex. ADC in the female group had a statistical difference between different age groups. The ADC and f in the male group were lower than those in the female group (<0.05); however, there was no statistical difference in ADC between genders.

Conclusion: IVIM parameters in healthy Chinese volunteers provided good consistency. There was a negative correlation between ADC and age in the female group.

Download full-text PDF

Source
http://dx.doi.org/10.1177/02841851211006311DOI Listing

Publication Analysis

Top Keywords

ivim parameters
12
myocardium microcirculation
8
healthy chinese
8
chinese population
8
cardiac magnetic
8
magnetic resonance
8
intravoxel incoherent
8
incoherent motion
8
motion imaging
8
microcirculation study
4

Similar Publications

Myocardial microcirculation in athletes and its relationship with cardiac remodeling (CR) and myocardial fibrosis (MF) are not fully understood. We prospectively enrolled 174 athletes and 54 healthy sedentary controls for intravoxel incoherent motion (IVIM) diffusion-weighted imaging of cardiac magnetic resonance imaging. Athletes exhibited significantly lower fast apparent diffusion coefficient (ADC) and perfusion fraction (f) in 16 myocardial segments and each blood supply area compared to controls ( < 0.

View Article and Find Full Text PDF

A Method for Imaging the Ischemic Penumbra with MRI using IVIM.

AJNR Am J Neuroradiol

January 2025

From the Department of Radiology, Medical Physics (MML, TJC), Department of Interventional Radiology (NS, GAC), Department of Surgery and Large Animal Studies (MAN), and the Department of Statistics (MG), University of Chicago, Chicago, IL, USA; Department of Anesthesiology (SPR), University of Illinois, Chicago, IL, USA; Department of Radiology (MSS), University of Massachusetts Chan Medical School, Worcester, MA, USA; Department of Radiology, Biomedical Engineering and Imaging Institute (Current affiliation MML), Icahn School of Medicine at Mount Sinai, New York, NY, USA; Mount Carmel Health Systems (Current affiliation GAC), Columbus, OH, USA.

Background And Purpose: In acute ischemic stroke, the amount of "local" CBF distal to the occlusion, i.e. all blood flow within a region whether supplied antegrade or delayed and dispersed through the collateral network, may contain valuable information regarding infarct growth rate and treatment response.

View Article and Find Full Text PDF

Multiparametric MRI is a promising technique for noninvasive structural and functional imaging of the kidneys that is gaining increasing importance in clinical research. Still, there are no standardized recommendations for analyzing the acquired images and there is a need to further evaluate the accuracy and repeatability of currently recommended MRI parameters. The aim of the study was to evaluate the test-retest repeatability of functional renal MRI parameters using different image analysis strategies.

View Article and Find Full Text PDF

Quantitative analysis of pseudo-diffusion in diffusion-weighted magnetic resonance imaging (DWI) data shows potential for assessing fetal lung maturation and generating valuable imaging biomarkers. Yet, the clinical utility of DWI data is hindered by unavoidable fetal motion during acquisition. We present IVIM-morph, a self-supervised deep neural network model for motion-corrected quantitative analysis of DWI data using the Intra-voxel Incoherent Motion (IVIM) model.

View Article and Find Full Text PDF

Incorporating spatial information in deep learning parameter estimation with application to the intravoxel incoherent motion model in diffusion-weighted MRI.

Med Image Anal

November 2024

Department of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway; Department of Circulation and Medical Imaging, NTNU - Norwegian University of Science and Technology, Trondheim, Norway.

In medical image analysis, the utilization of biophysical models for signal analysis offers valuable insights into the underlying tissue types and microstructural processes. In diffusion-weighted magnetic resonance imaging (DWI), a major challenge lies in accurately estimating model parameters from the acquired data due to the inherently low signal-to-noise ratio (SNR) of the signal measurements and the complexity of solving the ill-posed inverse problem. Conventional model fitting approaches treat individual voxels as independent.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!