Nuclear mA reader YTHDC1 regulates the scaffold function of LINE1 RNA in mouse ESCs and early embryos.

Protein Cell

Institute for Regenerative Medicine, Shanghai East Hospital, Shanghai Key Laboratory of Signaling and Disease Research, Frontier Science Center for Stem Cell Research, School of Life Sciences and Technology, Tongji University, Shanghai, 200120, China.

Published: June 2021

N-methyladenosine (mA) on chromosome-associated regulatory RNAs (carRNAs), including repeat RNAs, plays important roles in tuning the chromatin state and transcription, but the intrinsic mechanism remains unclear. Here, we report that YTHDC1 plays indispensable roles in the self-renewal and differentiation potency of mouse embryonic stem cells (ESCs), which highly depends on the mA-binding ability. Ythdc1 is required for sufficient rRNA synthesis and repression of the 2-cell (2C) transcriptional program in ESCs, which recapitulates the transcriptome regulation by the LINE1 scaffold. Detailed analyses revealed that YTHDC1 recognizes mA on LINE1 RNAs in the nucleus and regulates the formation of the LINE1-NCL partnership and the chromatin recruitment of KAP1. Moreover, the establishment of H3K9me3 on 2C-related retrotransposons is interrupted in Ythdc1-depleted ESCs and inner cell mass (ICM) cells, which consequently increases the transcriptional activities. Our study reveals a role of mA in regulating the RNA scaffold, providing a new model for the RNA-chromatin cross-talk.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8160034PMC
http://dx.doi.org/10.1007/s13238-021-00837-8DOI Listing

Publication Analysis

Top Keywords

nuclear reader
4
ythdc1
4
reader ythdc1
4
ythdc1 regulates
4
regulates scaffold
4
scaffold function
4
function line1
4
line1 rna
4
rna mouse
4
escs
4

Similar Publications

This paper reports an experimental study on the effects of extreme temperature on human bronchial epithelial (HBE) cells encapsulated in 3D printed samples. Well plates of the 3D printed samples were exposed to three levels of temperature (37 °C, 45 °C, and 55 °C, respectively) for a duration of 10 min. Cells' responses, specifically cell viability and oxidative stress, were quantified using Hoechst 33342, Sytox, and Mitosox stains, with intensity measurements obtained via a plate reader.

View Article and Find Full Text PDF

Feasibility of AI as first reader in the 4-IN-THE-LUNG-RUN lung cancer screening trial: impact on negative-misclassifications and clinical referral rate.

Eur J Cancer

December 2024

Institute for Diagnostic Accuracy, Groningen, the Netherlands; Faculty of Medical Sciences, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands. Electronic address:

Background: Lung cancer screening (LCS) with low-dose CT (LDCT) reduces lung-cancer-related mortality in high-risk individuals. AI can potentially reduce radiologist workload as first-read-filter by ruling-out negative cases. The feasibility of AI as first reader was evaluated in the European 4-IN-THE-LUNG-RUN (4ITLR) trial, comparing its negative-misclassifications (NMs) to those of radiologists and the impact on referral rates.

View Article and Find Full Text PDF

Following the publication of this paper, it was drawn to the Editor's attention by a concerned reader that the IL‑1 protein data shown in the western blotting data in Fig. 5A on p. 1905, the hippocampal images shown in Fig.

View Article and Find Full Text PDF

Background/aim: The recently published Node-Reporting and Data System (Node-RADS) can aid the characterization of lymph nodes in cross-sectional imaging. This study investigated the Node-RADS system in computed tomography (CT) to characterize lymph nodes in esophageal cancer.

Patients And Methods: Overall, 126 patients (15 female, 11.

View Article and Find Full Text PDF

Ultra-fast [F]florbetapir PET imaging using the uMI Panorama PET/CT system.

EJNMMI Phys

December 2024

Department of Nuclear Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Center for Rare Diseases Research, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, 1# Shuaifuyuan, Dongcheng District, Beijing, 100730, China.

Background: There is a need for faster amyloid PET scans to reduce patients' discomfort, minimize movement artifacts, and increase throughput. The recently introduced uMI Panorama PET/CT system featuring enhanced spatial resolution and sub-200ps TOF offers the potential for shorter scan duration without sacrificing image quality or efficacy to detect Aβ deposition. The study aims to establish a faster acquisition protocol for [F]florbetapir PET imaging using digital PET/CT scanner uMI Panorama, while ensuring adequate image quality and amyloid-β (Aβ) detectability comparable to the standard 10-minute scan.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!