Introduction: Currently there is no consensus how hindfoot alignment (HA) should be assessed in CBCT scans. The aim of this study is to investigate how the reliability is affected by the anatomical structures chosen for the measurement.
Materials And Methods: Datasets consisting of a Saltzman View (SV) and a CBCT of the same foot were acquired prospectively and independently assessed by five raters regarding HA. In SVs the HA was estimated as follows: transversal shift between tibial shaft axis and heel contact point (1); angle between tibial shaft axis and a tangent at the medial (2) or lateral (3) calcaneal wall. In CBCT the HA was estimated as follows: transversal shift between the centre of the talus and the heel contact point (4); angle between a perpendicular line and a tangent at the medial (5) or lateral (6) calcaneal wall; angle between the distal tibial surface and a tangent at the medial calcaneal wall (7). Intraclass correlation coefficients (ICC) were calculated to assess inter-rater reliability. A linear regression was performed to compare the different measurement regarding their correlation.
Results: 32 patients were included in the study. The ICCs for the measurements 1-7 were as follows: (1) 0.924 [95% CI 0.876-0.959] (2) 0.533 [95% CI 0.377-0.692], (3) 0.553 [95% CI 0.399-0.708], (4) 0.930 [95% CI 0.866-0.962], (5) 0.00 [95% CI - 0.111 to 0.096], (6) 0.00 [95% CI - 0.103 to 0.111], (7) 0.152 [95% CI 0.027-0.330]. A linear regression between measurement 1 and 4 showed a correlation of 0.272 (p = 0.036).
Conclusions: It could be shown that reliability of measuring HA depends on the investigated anatomical structure. Placing a tangent along the calcaneus (2, 3, 5, 6, 7) was shown to be unreliable, whereas determining the weight-bearing heel point (1, 4) appeared to be a reliable approach. The correlation of the measurement workflows is significant (p = 0.036), but too weak (0.272) to be used clinically.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9522738 | PMC |
http://dx.doi.org/10.1007/s00402-021-03904-1 | DOI Listing |
J Exp Orthop
October 2024
Department of Orthopaedics and Traumatology, Aix Marseille Univ, APHM, CNRS, ISM, Sainte-Marguerite Hospital Institute for Locomotion Marseille France.
Purpose: This study assessed the measurements of the medial posterior tibial slope (MPTS) using long radiographs and three-dimensional (3D) computed tomography (CT) scans and compared them to measurements taken on short lateral knee radiographs. The study aimed to identify whether the at-risk slope measurements previously defined on the short radiographs would be similar to long radiographs and 3D CT scans.
Methods: A retrospective radiological review of 52 cases, who underwent planning for a slope-changing high tibial osteotomy and had short and long lateral radiographs and 3D CT scans of the tibia.
J Shoulder Elbow Surg
August 2024
Queensland Unit for Advanced Shoulder Research, Queensland University of Technology, Brisbane, Queensland, Australia; Australian Research Council Industrial Transformation Training Centre for Joint Biomechanics, Queensland University of Technology, Brisbane, Queensland, Australia.
Cureus
July 2024
Orthodontics and Dentofacial Orthopedics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, IND.
Introduction: En-masse maxillary anterior retraction is necessary to attain an esthetic profile in Angle's class I bimaxillary dentoalveolar protrusion and Angle's class II division 1 malocclusion. The objective of this study was to evaluate configurational relationships between maxillary incisors and incisive canal in Angle's class I bialveolar protrusion and Angle's class II division 1 malocclusion by cone-beam computed tomography (CBCT).
Methods: A total of 108 adult CBCT scans of 54-skeletal class I bialveolar protrusion and 54-skeletal class II division 1 malocclusions were retrospectively analyzed.
Med Phys
September 2024
Dept. of Medical Physics, Cross Cancer Institute, Edmonton, Alberta, Canada.
Background: The Alberta rotating biplanar linac-MR has a 0.5 T magnetic field parallel to the beamline. When developing a new linac-MR system, interactions of charged particles with the magnetic field necessitate careful consideration of skin dose and tissue interface effects.
View Article and Find Full Text PDFPract Radiat Oncol
September 2024
Department of Radiation Oncology, New York University Langone Health and Perlmutter Cancer Center, New York, New York. Electronic address:
Purpose: With transition from supine to prone position, tenting of the pectoralis major occurs, displacing the muscle from the chest wall and shifting the level I and II axillary spaces. For patients for whom we aim to treat the level I and II axillae using the prone technique, accurate delineation of these nodal regions is necessary. Although different consensus guidelines exist for delineation of nodal anatomy in supine position, to our knowledge, there are no contouring guidelines in the prone position that account for this change in nodal anatomy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!