Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: In-hospital cardiac arrest is a medical emergency that occurs on a regular basis. As patients most at risk for an in-hospital cardiac arrest are usually positioned on a dynamic mattress, it is important to measure the effect of mattress compressibility on chest compression quality during cardiopulmonary resuscitation (CPR). High-quality CPR is essential for patient survival and good neurological outcome.
Aims And Objectives: To examine the effect of an inflated dynamic overlay mattress on chest compression quality during CPR and to explore the predictive effect of health care providers' anthropometric factors, hand positioning and mattress type on chest compression frequency and depth.
Design: Manikin-based single-blinded randomised controlled trial.
Methods: Nursing students (N = 70) were randomised to a control (viscoelastic foam mattress) or intervention group (inflated dynamic overlay mattress on top of a viscoelastic foam mattress) and had to perform chest compressions over a 2-minute period. Compression rate, depth and hand positioning were registered. The 2015 European Resuscitation Council (ERC) guidelines were used as a reference.
Results: The mean difference in chest compression depth between control and intervention groups was 2.86 mm (P = .043). Both groups met the guidelines for adequate chest compression quality, as recommended by the ERC. A predictive effect of health care providers' body height and weight, mattress type and hand positioning on compression depth could be demonstrated (P = .004).
Conclusions: CPR in bedridden patients on a dynamic overlay mattress has a negative effect on the quality of chest compressions. Mean chest compression depth decreases significantly. However, clinical significance of the results may be debatable. Mattress type, body weight and hand positioning appear to be significant predictors for adequate chest compression depth.
Relevance To Clinical Practice: A firm surface under the patient is needed during CPR. Special attention must be paid to correct hand positioning during CPR.