Background: Adult and paediatric basic life support (BLS) training are often conducted via group training with an accredited instructor every 24 months. Multiple studies have demonstrated a decline in the quality of cardio-pulmonary resuscitation (CPR) performed as soon as 3-month post-training. The 'Resuscitation Quality Improvement' (RQI) programme is a quarterly low-dose, high-frequency training, based around the use of manikins connected to a cart providing real-time and summative feedback. We aimed to evaluate the effects of the RQI Programme on CPR psychomotor skills in UK hospitals that had adopted this as a method of BLS training, and establish whether this program leads to increased compliance in CPR training.

Methods: The study took place across three adopter sites and one control site. Participants completed a baseline assessment without live feedback. Following this, participants at the adopter sites followed the RQI curriculum for adult CPR, or adult and infant CPR. The curriculum was split into quarterly training blocks, and live feedback was given on technique during the training session via the RQI cart. After following the curriculum for 12/24 months, participants completed a second assessment without live feedback.

Results: At the adopter sites, there was a significant improvement in the overall score between baseline and assessment for infant ventilations (N = 167, p < 0.001), adult ventilations (n = 129, p < 0.001), infant compressions (n = 163, p < 0.001) adult compressions (n = 205, p < 0.001), and adult CPR (n = 249, p < 0.001). There was no significant improvement in the overall score for infant CPR (n = 206, p = 0.08). Data from the control site demonstrated a statistically significant improvement in mean score for adult CPR (n = 22, p = 0.02), but not for adult compressions (N = 18, p = 0.39) or ventilations (n = 17, p = 0.08). No statistically significant difference in improvement of mean scores was found between the grouped adopter sites and the control site. The effect of the duration of the RQI curriculum on CPR performance appeared to be minimal in this data set. Compliance with the RQI curriculum varied by site, one site maintained hospital compliance at 90% over a 1 year period, however compliance reduced over time at all sites.

Conclusions: This data demonstrated an increased adherence with guidelines for high-quality CPR post-training with the RQI cart, for all adult and most infant measures, but not infant CPR. However, the relationship between a formalised quarterly RQI curriculum and improvements in resuscitation skills is not clear. It is also unclear whether the RQI approach is superior to the current classroom-based BLS training for CPR skill acquisition in the UK. Further research is required to establish how to optimally implement the RQI system in the UK and how to optimally improve hospital wide compliance with CPR training to improve the outcomes of in-hospital cardiac arrests.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8058602PMC
http://dx.doi.org/10.1186/s41077-021-00168-yDOI Listing

Publication Analysis

Top Keywords

adopter sites
16
rqi curriculum
16
cpr
13
bls training
12
control site
12
adult cpr
12
infant cpr
12
improvement score
12
0001 adult
12
rqi
10

Similar Publications

Ozone (O) is a significant contributor to air pollution and the main constituent ofphotochemical smog that plagues China. Nitrogen dioxide (NO) is a significant air pollutant and a critical trace gas in the Earth's atmosphere. The presence of O and NO has detrimental effects on human health, the ecosystem, and agricultural production.

View Article and Find Full Text PDF

Accurate meteorological observation data is of great importance to human production activities. Meteorological observation systems have been advancing toward automation, intelligence, and informatization. Yet, instrumental malfunctions and unstable sensor node resources could cause significant deviations of data from the actual characteristics it should reflect.

View Article and Find Full Text PDF

While single-atom catalysts (SACs) have been extensively investigated as a high-atom-efficiency heterogeneous catalyst for peroxymonosulfate (PMS) oxidation reaction, the stable constructing and activation efficacy of the reaction sites remains less clarified. Herein, we employed gelatin as a N,O-bidentate ligand for Co (II) to form for a N-doped carbon precursor, while introducing NaCl as a template agent to induce the adoption of a Co-N conformation and disorganize the Co-O moiety. This approach facilitates uniform spatial isolation and atomic-level dispersion of Co atoms within the aerogel, effectively inhibiting the aggregation of Co during synthesis and enabling precise and controllable preparation of Co single-atom catalysts (SACs).

View Article and Find Full Text PDF

Robotic Resection of an Ectopic Parathyroid Gland: A Systematic Review.

Cureus

December 2024

General Surgery, East Sussex Healthcare NHS Trust, Brighton and Hove, GBR.

Ectopic parathyroid glands result from abnormal migration during development. If not detected promptly, they can lead to persistent or recurrent primary hyperparathyroidism (pHPT). Inferior parathyroid glands are typically located in the anterior mediastinum, while superior parathyroid glands are often near the tracheoesophageal groove, both of which contribute to pHPT.

View Article and Find Full Text PDF

Multinary tellurides with complex structures and narrow bandgaps are potential candidates for thermoelectric applications. Herein, we report the syntheses of two new ternary polytellurides, BaSiTe and BaSiTe(Te). Both title structures adopt unprecedented structure types.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!