Thermal discomfort in healthcare workers during the COVID-19 pandemic.

Med Lav

INAIL Settore Certificazione, Verifica e Ricerca. UOT di Avellino, Italia.

Published: April 2021

Introduction: Due to the COVID-19 pandemic, healthcare workers are now required to use additional personal protective equipment (PPEs) to protect themselves against the virus. That led to an increased clothing insulation which is negatively affecting the perceived healthcare workers' thermal sensation.

Objectives: While demonstrating through software simulations the potential level of thermal discomfort healthcare workers involved in the COVID-19 emergency can be subjected to, this work aims at identifying measures to improve thermal sensation perception and acceptable thermal conditions for medical personnel.

Methods: After having obtained the insulation values of individual clothing used by staff during COVID-19 emergency through the use of a thermal well-being evaluation software, the Fanger indexes (PMV - Predicted Mean Vote and PPD - Predicted Percentage of Dissatisfied) were calculated in order to estimate staff satisfaction to microclimatic conditions.

Results: The use of COVID-19 additional PPEs with an air temperature equal to 22 °C (normally considered optimal) brings the PMV index equal to 0.6, which corresponds to 11.8 % being unsatisfied (PPD) due to perceived heat.

Discussion: The use of additional protective devices significantly increases the clothing insulation level, facilitating the onset of conditions of thermal discomfort in the health workers. Workers engaged in the execution of nasopharyngeal swabs were most affected by the summer weather conditions and certainly represent the most critical category, for which it would be recommended to implement a higher turnover of service to reduce individual exposure time and consequent discomfort.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8095330PMC
http://dx.doi.org/10.23749/mdl.v112i2.10621DOI Listing

Publication Analysis

Top Keywords

thermal discomfort
12
healthcare workers
12
discomfort healthcare
8
covid-19 pandemic
8
clothing insulation
8
covid-19 emergency
8
thermal
7
workers
5
covid-19
5
healthcare
4

Similar Publications

Climate change and air pollution are pressing public health concerns, necessitating monitoring of their impact, particularly on respiratory diseases like obstructive lung diseases. This retrospective study analyzed medical records of patients hospitalized at the Warmia and Mazury Centre for Pulmonary Diseases in Olsztyn, Poland (2012-2021) for asthma and chronic obstructive pulmonary disease (COPD) exacerbations. Data included meteorological factors such as temperature, humidity, wind speed, precipitation, and levels of PM2.

View Article and Find Full Text PDF

Objective: Aim: The purpose was to improve the results of treatment of chronic diseases of the lower extremities veins by using endovenous high-frequency electric welding in automatic mode, and to evaluate the obtained results..

Patients And Methods: Materials and methods: The results of treatment of 146 patients with chronic diseases of the lower extremities veins in the period from 2018 to 2023 were analyzed.

View Article and Find Full Text PDF

This work is an application of experimental temperature data previously collected in a residential building in Douala, Cameroon, in order to analyze thermal discomfort. The data was collected according to three occupancy scenarios over 12 month period using thermohygrometer sensors. The temperature data are analysed in comparison with the comfortable temperature range from 24°C to 28°C.

View Article and Find Full Text PDF

Introduction: Genitourinary Syndrome of Menopause (GSM) defines a set of symptoms associated with an estrogen deficit involving alterations in organs genitourinary and that results in several urinary, genital, and sexual alterations. Brazilian women live about a third of their life after menopause, where hormonal changes occur along with clinical manifestations, characterized by vaginal and vulvar dryness, burning sensation, discomfort, vulvovaginal irritation, lack of lubrication, dyspareunia and urinary incontinence. Fractionated photothermolysis and radiofrequency systems, alone or in combination were tested to improve GSM.

View Article and Find Full Text PDF

TRPM8 and TRPA1 ideal targets for treating cold-induced pain.

Eur J Med Chem

January 2025

Department of Pharmacy, General Hospital of Northern Theater Command, Shenyang, 110840, People's Republic of China. Electronic address:

Article Synopsis
  • TRP channels are crucial for sensing external temperature changes and are found in both the peripheral and central nervous systems, impacting various sensory responses and physiological functions.
  • In colder environments, TRPM8 and TRPA1 channels detect cold and are key to understanding pain related to low temperatures and neuropathic pain.
  • The paper reviews the structural features, biosynthetic pathways, and chemical synthesis of TRPM8 and TRPA1 inhibitors and provides insights into pharmacological strategies for treating pain linked to these channels.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!