Background: Coronary artery fistula (CAF) is a rare congenital anomaly with a challenging scenario in children. This study reports our experience in transcatheter closure of CAF with Nit-Occlude PDA coil and midterm clinical and imaging follow-up.

Methods: Twelve children with congenital CAF between 2009 and 2019, mean age 2.05 ± 2.05 years (4 days to 7.2 years), mean weight 8.8 ± 4.83 (2.8-17 kg), who underwent transcatheter closure with PFM coil at the Namazi hospital, Shiraz, Iran, were reported. Echocardiography and electrocardiogram were done before and after the procedure (early, 3, and 6 months after), and Multi-slice computerized tomography or conventional coronary angiography was performed at least one year after closure.

Results: In a median follow-up of 5.5 years (range 13 months to 8 years), retrogradely closed fistula had no residual, and the fistula tract was wholly occluded, but in most anterogradely closed fistula, had a small residual, which made the fistula tract open and need additional coil closure.

Conclusions: Transcatheter closure of CAF with PFM coil is feasible and effective with low mortality and morbidity, although antegrade closure with this device may be accompanied by residual shunt and need for multiple coil insertion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8056487PMC
http://dx.doi.org/10.1186/s12872-021-01999-3DOI Listing

Publication Analysis

Top Keywords

transcatheter closure
16
coronary artery
8
artery fistula
8
closure caf
8
pfm coil
8
closed fistula
8
residual fistula
8
fistula tract
8
fistula
6
coil
6

Similar Publications

Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience.

Korean Circ J

November 2024

Department of Structural Heart Disease, National Center for Cardiovascular Disease & Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, People's Republic of China.

Background And Objectives: There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.

Methods: Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).

View Article and Find Full Text PDF

Femoral or Radial Secondary Access in TAVR: A Subanalysis From the Multicenter PULSE Registry.

JACC Cardiovasc Interv

December 2024

Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Center for Population Health Innovation, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Lübeck/Kiel, Lübeck, Germany; BG University Hospital Bergmannsheil, Bochum, Germany.

Background: Transradial secondary access (TR-SA) may serve as an alternative to the traditional femoral secondary access (TF-SA) for pigtail placement in transcatheter aortic valve replacement (TAVR).

Objectives: The aim of this study was to assess the incidence of secondary access-related vascular complications after TR-SA or TF-SA in TAVR.

Methods: The PULSE (Plug or sUture based vascuLar cloSurE after TAVR) registry retrospectively evaluated data of 10,120 patients who underwent transfemoral TAVR at 10 heart centers from 2016 to 2021.

View Article and Find Full Text PDF

The ruptured sinus of Valsalva aneurysm (RSOV), a rare but well-recognized clinical entity, is invariably a form of left-to-right shunt due to rupture into right-sided chambers. It causes profound hemodynamic effects, especially when the rupture is acute. Like most other left-to-right shunts, it was only a matter of time before this rare defect also became amenable to transcatheter closure (TCC).

View Article and Find Full Text PDF

Background: Secundum Atrial Septal Defects (ASDs) are the most common type of atrial septal defects. Today, using different types of occluders, transcatheter closure is widely used to treat ASD and has replaced the surgical procedure in anatomically suitable patients. This study was performed to evaluate the short-term clinical outcomes of treatment of adult patients requiring an ASD device closure referred to Shahid Chamran Cardiovascular Center in Isfahan, Iran.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!