Ultrasound attenuation coefficient estimation (ACE) has great diagnostic potential for fatty liver detection and assessment. In a previous study, we proposed a reference phantom-free ACE method, called reference frequency method (RFM), which does not require a calibrated phantom for normalization. The power of each frequency component can be normalized by the power of an adjacent frequency component in the spectrum to cancel system-dependent effects such as focusing and time gain compensation (TGC). RFM demonstrated accurate ACE in both phantom and in in-vivo liver studies. However, our study also showed that the robustness and penetration of RFM were affected by noise in the ACE signals. Here we propose a noise suppression (NS) and a signal-to-noise ratio (SNR) quality control method to reduce the influence of noise on ACE-RFM performance. The proposed methods were tested in harmonic ACE because harmonic imaging is a more frequently used mode than fundamental imaging for abdominal applications. After applying the NS and SNR control methods, the noise-induced bias for attenuation estimation in harmonic ACE was effectively reduced, leading to significantly improved effective penetration depth. The proposed methods directly measure the noise spectrum of the ultrasound system, which can also be adapted to other spectrum-based ACE methods, such as the reference phantom method and the spectra shift method.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8344359PMC
http://dx.doi.org/10.1109/TUFFC.2021.3074293DOI Listing

Publication Analysis

Top Keywords

noise suppression
8
ultrasound attenuation
8
attenuation coefficient
8
coefficient estimation
8
frequency component
8
proposed methods
8
harmonic ace
8
ace
7
noise
5
method
5

Similar Publications

Article Synopsis
  • Many experimental setups in quantum science rely on laser fields for controlling states, but this control can suffer from issues related to optical phase noise.
  • Researchers introduced an optical feedforward technique to minimize laser phase noise during the stimulated Raman adiabatic passage for transferring ultracold RbCs molecules.
  • After conducting over 100 transfers on individual molecules, they achieved a notable transfer efficiency of 98.7(1)%, which is primarily constrained by the intensity of the lasers used.
View Article and Find Full Text PDF

Passive and active suppression of transduced noise in silicon spin qubits.

Nat Commun

January 2025

Department of Physics and Astronomy, and Institute of Applied Physics, Seoul National University, Seoul, Korea.

Addressing and mitigating decoherence sources plays an essential role in the development of a scalable quantum computing system, which requires low gate errors to be consistently maintained throughout the circuit execution. While nuclear spin-free materials, such as isotopically purified silicon, exhibit intrinsically promising coherence properties for electron spin qubits, the omnipresent charge noise, when converted to magnetic noise under a strong magnetic field gradient, often hinders stable qubit operation within a time frame comparable to the data acquisition time. Here, we demonstrate both open- and closed-loop suppression techniques for the transduced noise in silicon spin qubits, resulting in a more than two-fold (ten-fold) improvement of the inhomogeneous coherence time (Rabi oscillation quality) that leads to a single-qubit gate fidelity of over 99.

View Article and Find Full Text PDF

Deep learning-enabled filter-free fluorescence microscope.

Sci Adv

January 2025

Engineering Research Center of Optical Instrument and System, the Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China.

Optical filtering is an indispensable part of fluorescence microscopy for selectively highlighting molecules labeled with a specific fluorophore and suppressing background noise. However, the utilization of optical filtering sets increases the complexity, size, and cost of microscopic systems, making them less suitable for multifluorescence channel, high-speed imaging. Here, we present filter-free fluorescence microscopic imaging enabled with deep learning-based digital spectral filtering.

View Article and Find Full Text PDF

The thickness loss caused by corrosion is a vital factor that threatens the health of shell structures. It is significant to perform a non-destructive quantitative evaluation of corrosion-thinning defects in plate structures. Based on the laser ultrasonic guided wavefield scanning technology, this paper proposes an instantaneous wavenumber multi-shot fusion method, which improves the performance of the instantaneous wavenumber imaging method.

View Article and Find Full Text PDF

Aim: To evaluate the impact of different b-value combinations on synthetic diffusion-weighted imaging (sDWI) and determine the sDWI with an optimal b-value combination for prostatic cancer (PCa) diagnosis.

Material And Methods: A retrospective analysis of 68 patients with abnormal prostate-specific antigen (PSA) was conducted. The sDWI images with b value of 1500 s/mm were separately reconstructed by the following five b-value combinations: b=0, 200s/mm (sDWI); b=600, 800s/mm (sDWI); b=0, 600s/mm (sDWI); b=200, 800s/mm sDWI); b=0, 800s/mm (sDWI).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!