Comparison of diagnosis of cracked tooth using contrast-enhanced CBCT and micro-CT.

Dentomaxillofac Radiol

Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China.

Published: October 2021

Objectives: To evaluate the diagnostic accuracy using sodium iodide (NaI) and dimethyl sulfoxide (DMSO) as contrast agent in cone beam computed tomography (CBCT) scanning, and compare this with micro-CT.

Methods: 18 teeth were cracked artificially by soaking them cyclically in liquid nitrogen and hot water. After pre-treatment with artificial saliva, the teeth were scanned in four modes: CBCT routine scanning without contrast agent (RS); CBCT with meglumine diatrizoate (MD) as contrast agent (ES1); CBCT with NaI + DMSO as contrast agent (ES2); and micro-CT (mCT). The number of crack lines was evaluated in all four modes. Depth of crack lines and number of cracks presented from the occlusal surface to the pulp cavity (Np) in ES2 and micro-CT images were evaluated.

Results: There were 63 crack lines in all 18 teeth. 45 crack lines were visible on ES2 images as against four on the RS and ES1 images (0.05) and 37 on micro-CT images (0.05). Further, 34 crack lines could be observed on both ES2 and micro-CT images, and the average depth presented on ES2 images was 4.56 ± 0.88 mm and 3.89 ± 1.08 mm on micro-CT images (0.05). More crack lines could be detected from the occlusal surface to the pulp cavity on ES2 images than on micro-CT images (22 11).

Conclusion: CBCT with NaI +DMSO as the contrast agent was equivalent to micro-CT for number of crack lines and better for depth of crack lines. NaI + DMSO could be a potential CBCT contrast agent to improve diagnostic accuracy for cracked tooth.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8474134PMC
http://dx.doi.org/10.1259/dmfr.20210003DOI Listing

Publication Analysis

Top Keywords

crack lines
32
contrast agent
24
micro-ct images
20
es2 micro-ct
12
es2 images
12
images 005
12
images
9
cracked tooth
8
micro-ct
8
diagnostic accuracy
8