Unlike immunoglobulin (Ig)G pneumococcal polysaccharide (PnPS)-antibodies, PnPS IgA and IgM-antibodies are not routinely determined for the assessment of immunocompetence. It is not yet known whether an isolated inability to mount a normal IgM or IgA-PnPS response should be considered a relevant primary antibody deficiency (PAD). We studied the clinical relevance of anti-PnPS IgM and IgA-assays in patients with suspected primary immunodeficiency in a large teaching hospital in 's-Hertogenbosch, the Netherlands. Serotype-specific-PnPS IgG assays were performed; subsequently, 23-valent-PnPS IgG assays (anti-PnPS IgG assays), and later anti-PnPS IgA and IgM assays, were performed in archived material (240 patients; 304 samples). Eleven of 65 pre- and six of 10 post-immunization samples from good responders to PnPS serotype-specific IgG testing had decreased anti-PnPS IgA and/or IgM titres. Of these, three pre- and no post-immunization samples were from patients previously classified as 'no PAD'. Determination of anti-PnPS IgA and IgM in addition to anti-PnPS IgG did not reduce the need for serotype-specific PnPS IgG testing to assess immunocompetence [receiver operating characteristic (ROC) analysis of post-immunization samples: anti-PnPS IgA + IgG area under the curve (AUC) = 0.80, 95% confidence interval (CI) = 0.63-0.97; anti-PnPS IgM + IgG AUC 0.80, 95% CI = 0.62-0.98; anti-PnPS IgA + IgG + IgM AUC = 0.71, 95% CI = 0.51-0.91; anti-PnPS IgG AUC = 0.93, 95% CI = 0.85-1.00]. Our data show that patients classified as having an intact antibody response based on measurement of serotype-specific PnPS IgG can still display impaired anti-PnPS IgM and IgA responses, and that the additional measurement of anti-PnPS IgA and IgM could not reduce the need for serotype-specific IgG testing. Future studies are needed to investigate the clinical relevance of potential 'specific IgA or IgM antibody deficiency' in patients with recurrent airway infections in whom no PAD could be diagnosed according to the current definitions.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8274160 | PMC |
http://dx.doi.org/10.1111/cei.13605 | DOI Listing |
Clin Exp Immunol
August 2021
Department of Tranzo, Tilburg University, Tilburg, the Netherlands.
Unlike immunoglobulin (Ig)G pneumococcal polysaccharide (PnPS)-antibodies, PnPS IgA and IgM-antibodies are not routinely determined for the assessment of immunocompetence. It is not yet known whether an isolated inability to mount a normal IgM or IgA-PnPS response should be considered a relevant primary antibody deficiency (PAD). We studied the clinical relevance of anti-PnPS IgM and IgA-assays in patients with suspected primary immunodeficiency in a large teaching hospital in 's-Hertogenbosch, the Netherlands.
View Article and Find Full Text PDFJ Clin Immunol
January 2013
Clinic for Immunodeficiencies, Paediatric Pulmonology, Allergy and Neonatology, Hanover Medical School, Carl-Neuberg Str. 1, 30625, Hanover, Germany.
Purpose: A poor antibody response of IgM and IgA antibodies upon vaccination with pneumococcal polysaccharides (PnPS) is discussed as independent risk factors for bronchiectasis in patients with antibody deficiency syndrome (ADS) receiving immunoglobulin replacement therapy. However, the kinetics of the specific IgM and IgA response to vaccination with multivalent pneumococcal polysaccharides requires a more detailed knowledge. In this study we aimed i) to develop a standardised multivalent PnPS-IgM and IgA-ELISA, and ii) to compare the sensitivity of the multivalent to the serotype specific antibody response, and iii) to determine the kinetics of the anti-PnPS IgM and IgA antibodies in healthy subjects.
View Article and Find Full Text PDFClin Diagn Lab Immunol
November 2004
Wyeth Vaccines Research, 401 N. Middletown Rd., 180/152A, Pearl River, NY 10965, USA.
Weight-based immunoglobulin G (IgG), IgM, IgA, and total Ig antibody assignments were made to human antipneumococcal standard reference serum lot 89-S, also known as lot 89-SF, for Streptococcus pneumoniae capsular polysaccharide (PnPs) serotypes 2, 6A, 8, 9N, 10A, 11A, 12F, 15B, 19A, 17F, 20, 22F, and 33F, as well as for C-polysaccharide (C-Ps), extending the standard's usefulness for pneumococcal vaccine evaluation beyond the original serotype 1, 3, 4, 5, 6B, 7F, 9V, 14, 18C, 19F, and 23F assignments (S. A. Quataert, C.
View Article and Find Full Text PDFImmunol Invest
August 2001
Wyeth-Lederle Vaccines, Rochester, New York, USA.
An enzyme-linked immunoassay (EIA) is described and evaluated which quantitates human antibodies to serotype specific S. pneumoniae polysaccharide (PnPs) in human sera. Based on the observations previously described by Koskela (1), native PnPs are used as coating antigens and sera are absorbed with a soluble pneumococcal absorbant material containing C-polysaccharide (CPs) to ensure measurement of serotype specific anti-PnPs antibodies.
View Article and Find Full Text PDFClin Diagn Lab Immunol
September 1995
Lederle-Praxis Biologicals, West Henrietta, New York 14586-9728, USA.
A human reference serum pool, lot 89-S, has been developed for use in quantitating concentrations of antibody to Streptococcus pneumoniae. Weight-based units have been assigned to antibodies to 11 pneumococcal polysaccharide (PnPs) serotypes (1, 3, 4, 5, 6B, 7F, 9V, 14, 18C, 19F, and 23F) by using enzyme-linked immunosorbent assay methodology and a human standard reference serum, USNRP IS 1644. The experimentally derived assignments for anti-PnPs antibodies of the immunoglobulin G (IgG), IgM, and IgA isotypes in lot 89-S correlate well to the separately determined immunoglobulin assignment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!