This work aimed to investigate the effect of different shim techniques, voxel sizes, and repetition time (TR) on using theT2 and T2* sequences to determine their optimum settings to investigate the quantification of iron in transfused dependent sickle cell patients. The effect of each of these parameters was investigated on phantoms of different Gadolinium (Gd) concentrations, on 10 volunteers and 25 patients using a1 5T MRI Philips scanner. No significant difference between the three shim techniques was noticed in either T2 or T2* sequence measurements. Pixel sizes of 1 × 1 and 2 × 2 mm provided optimum results for T2 measurements. At 1 × 1 mm pixel size the T2* measurements experienced less error in measurements than the size of 2.5 × 2.5 mm used in the literature. Even though the slice thickness variation did not provide any changes in T2 measurements, the 12 mm provided optimum T2* measurements. TR variation did not yield significant changes on either T2 or T2* measurements. These results indicate that both T2 and T2* sequences can be further improved by providing more reliable measurements and reducing acquisition time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8055987PMC
http://dx.doi.org/10.1038/s41598-021-88116-8DOI Listing

Publication Analysis

Top Keywords

t2* sequences
12
t2* measurements
12
quantification iron
8
iron transfused
8
transfused dependent
8
dependent sickle
8
sickle cell
8
cell patients
8
shim techniques
8
measurements
8

Similar Publications

Intradural extramedullary bronchogenic cysts (IEBCs) are exceedingly rare congenital entities, composed of respiratory epithelial cells derived from the anomalous development of the embryonic foregut. Due to their exceptionally low morbidity, only limited cases are available. Consequently, the clinical features and optimal therapeutic approach remain poorly understood.

View Article and Find Full Text PDF

Background: There is evidence that iron metabolism may play a role in the underlying pathophysiological mechanism of migraine. Studies using (=1/ ) relaxometry, a common MRI-based iron mapping technique, have reported increased values in various brain structures of migraineurs, indicating iron accumulation compared to healthy controls.

Purpose: To investigate whether there are short-term changes in during a migraine attack.

View Article and Find Full Text PDF

Background: Early diagnosis of prostate cancer can improve the survival rate of patients on the premise of high-quality images. The prerequisite for early diagnosis is high-quality images. ZOOMit is a method for high-resolution, zoomed FOV imaging, allowing diffusion-weighted images with high contrast and resolution in short acquisition times.

View Article and Find Full Text PDF

To explore the quantitative value of the T2mapping sequence in evaluating the early glenohumeral joint cartilage injury. A total of 92 patients with shoulder joint pain who underwent routine sequence and T2mapping sequence scanning in General Hospital of Ningxia Medical University from March 2023 to March 2024 were retrospectively collected as a case group. The patients were classified into tendinitis group, partial tear group and full tear group according to the degree of tendon injury.

View Article and Find Full Text PDF

Value of Abbreviated Magnetic Resonance Sequence in Hepatocellular Carcinoma Screening: A Systematic Review and Meta-analysis.

Acad Radiol

January 2025

Department of Maternal and Child Health, School of Public Health, Sun Yat-sen University, Guangzhou 510080, PR China (J.H.L.); Department of Social medicine, School of Public Health, Medical College of Soochow University, Suzhou, Jiangsu 215123, PR China (J.H.L.); Jiangsu Key Laboratory of Preventive and Translational Medicine for Geriatric Diseases, School of Public Health, Soochow University, Suzhou, Jiangsu 215123, PR China (J.H.L.).

Rationale And Objectives: To systematically review the diagnostic efficacy of abbreviated magnetic resonance imaging sequence (AMRI) screening for hepatocellular carcinoma (HCC).

Materials And Methods: Medline (via PubMed), EMbase, The Cochrane Library, Web of Science, CNKI, WanFang Data, and VIP databases were electronically searched to collect studies on the diagnostic efficacy of AMRI screening for HCC from inception to August 10th, 2024. Two reviewers independently screened literature, extracted data, and assessed the risk of bias of included studies using the Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2), then, the meta-analysis with a bivariate mixed-effects regression model was performed by using Stata 14.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!