A systematic literature review was conducted on studies comparing interspinous process (ISP) devices to traditional methods of posterior spinal instrumentation (pedicle screw-rod construct), in terms of indications of use, complications, pain assessment, estimated blood loss, length of hospital stay, reoperation rates, and return to work. The objective was to analyze, evaluate and summarize the current published literature on the proposed efficacy and clinical and surgical long-term outcomes of the ISP device in comparison to the traditional posterior spinal instrumentation (pedicle screw-rod construct). The ISP device is a minimally invasive and less disruptive alternative to traditional methods of posterior spinal instrumentation (pedicle screw-rod construct). However, very few published literature studies to date have reported the comparison of ISPs in terms of efficacy and clinical and surgical outcomes, to traditional posterior spinal instrumentation. A systematic literature review was performed in PubMed and Google Scholar to evaluate the results of published research that meet the defined inclusion and exclusion criteria and to analyze clinical indications and surgical outcomes of the ISP device compared to traditional methods of posterior spinal instrumentation (pedicle screw-rod construct). Inclusion criteria included keywords such as "ISP device, ISP, posterior spinal instrumentation, pedicle screw fixation, bilateral pedicle screws, interbody fusion with posterior spinal instrumentation, lumbar spinal stenosis, and posterior lumbar stability." No exclusion criteria keywords were included in this literature review. ISPs provide a high degree of spinal stability in multiple planes, including a decreased range of motion restriction in flexion-extension, and comparable results to bilateral pedicle screw (BPS) in axial rotation. The use of the ISP device in adjunct with an interbody fusion, ensures less estimated operative blood loss (EBL), shorter operative time, less bony exposure without the need for extensive soft tissue or muscle retraction, a decrease in the rate of pseudoarthrosis, and a shorter length of hospital stay (LOHS) when compared to the traditional posterior instrumentation (pedicle screw-rod construct). Based on the various published literature reviews noted throughout this research paper, it is safe to conclude, that an ISP device that is accompanied by interbody fusion, including posterior approaches posterior lumbar interbody fusion (PLIF) and transforaminal lumbar interbody fusion (TLIF); anterior approaches such as anterior interbody fusion (ALIF), and lateral approaches including direct lateral interbody fusion (DLIF), lateral lumbar interbody fusion (LLIF), extreme lateral interbody fusion (XLIF), is considered a credible and an effective minimally invasive option for the treatment of mild to moderate lumbar stenosis and stable low-grade spondylolisthesis (less than two) when compared to the traditional posterior spinal instrumentation of a pedicle screw-rod construct. Surgeons that are relatively new to the ISP technologies for spinal instrumentation would likely benefit from more clinical and surgical evidence of safety and efficacy in published peer-reviewed medical literature. Further clinical trials are needed to manifest the efficacy of ISPs regarding postoperative outcomes when compared to traditional posterior instrumentation techniques (pedicle screw-rod construct) with adjunct interbody fusions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8043769PMC
http://dx.doi.org/10.7759/cureus.13886DOI Listing

Publication Analysis

Top Keywords

spinal instrumentation
40
posterior spinal
36
interbody fusion
36
instrumentation pedicle
28
pedicle screw-rod
28
traditional posterior
24
screw-rod construct
24
compared traditional
16
posterior
13
spinal
12

Similar Publications

Atlantoaxial dislocation (AAD) is a serious condition in which the first two cervical vertebrae lose their anatomical position and stability. This may lead to neurological complications, including death. The treatment of AAD remains controversial, and posterior instrumentation with pedicle screw placement is one of the commonly used methods.

View Article and Find Full Text PDF

Pedicle Screw Placement in Pediatric and Adolescent Spinal Deformity Surgery: Does Tapping of the Pedicle Screw Tract Increase Safety?

J Pediatr Orthop

January 2025

Department of Orthopaedics, Division of Pediatrics and Adolescent Orthopaedic Surgery and Division of Spine Surgery, Washington University School of Medicine, St. Louis, MO.

Introduction: Since the development of pedicle screw fixation in the spine, safe placement has remained a crucial component in maximizing patient outcomes and mitigating pedicle screw-related complications. The purpose of this study is to investigate the utility of pedicle tapping in identifying pedicle breaches.

Methods: A pediatric spine surgery database was queried to identify a consecutive series of patients who underwent spinal deformity surgery utilizing pedicle screw fixation between May 2019 and October 2022.

View Article and Find Full Text PDF

Anterior cervical discectomy and fusion with self-locking standalone cage for the treatment of cervical degenerative disc disease in patients over 80 years.

J Orthop Traumatol

January 2025

Department of Orthopaedic Surgery, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai, 200032, China.

Background: The need for anterior cervical discectomy and fusion (ACDF) for cervical degenerative disc disease (CDDD) will probably grow dramatically in the geriatric population. However, ACDF with self-locking standalone cages in patients over 80 years has not yet been investigated. This study aimed to assess the clinical and radiographic results in patients over 80 years treated by ACDF with self-locking standalone cages.

View Article and Find Full Text PDF

Analysis of scoliosis rod deformation after cutting with a surgical rod cutter.

Spine Deform

January 2025

Department of Orthopedic Surgery, Children's Mercy Kansas City, Kansas City, Missouri, USA.

Purpose: Scoliosis is a complex multi-dimensional deformity of the spine that is common in children and adults. Of the various treatments for scoliosis, one is posterior spinal fusion with instrumentation. The rods typically used are composed of titanium or cobalt-chrome.

View Article and Find Full Text PDF

Biomechanical Principles of Spinal Deformity Correction in the Thoracolumbar Spine.

J Am Acad Orthop Surg

January 2025

From the Children's Mercy Hospital, Kansas City, MO (Shaw), Children's Health Ireland at Temple Street, Dublin, Ireland (O'Sullivan), the Department of Mechanical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada (Wang and Aubin), and the Sainte-Justine University Hospital Center, Montreal, Quebec, Canada (Wang and Aubin).

Thoracolumbar spinal deformities are a pervasive condition affecting the adolescent and adult patient population. These deformities represent three-dimensional alterations in the coronal, sagittal, and transverse planes with implication on the local, regional, and global alignment. With continued studies, the importance of the overall correction on long-term outcomes has been established.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!