Introduction: Transapical access (TA) transcatheter aortic valve implantation (TAVI) (TA-TAVI) represents one of the possible routes in patients with severe aortic stenosis (AS) who are not suitable for transfemoral access.

Aim: To assess early- and mid-term clinical outcomes after TA-TAVI.

Material And Methods: Patients with severe symptomatic AS undergoing TA-TAVI from November 2008 to December 2019 were enrolled. Clinical and procedural characteristics as well as clinical outcomes including all-cause mortality during 12-month follow-up were assessed.

Results: Sixty-one consecutive patients underwent TA-TAVI for native AS. Patients were elderly with median age of 80.0 (76.0-84.0) years; 55.7% were males. Median baseline EuroSCORE I and STS scores were 18.2% (11.6-27.7) and 4.8% (3.3-8.2), respectively. The procedural success rate was 96.7%. In-hospital, 30-day and 12-month mortality rates were 9.8%; 18.0% and 24.6%, respectively. The main periprocedural and in-hospital complications were bleeding complications (14.8%). The following factors were associated with 12-month mortality: previous cerebrovascular event (CVE), glomerular filtration rate (GFR), aortic valve area (AVA), right ventricular systolic pressure (RVSP) and serum level of N-terminal prohormone of brain natriuretic peptide (NT-proBNP) (RR for CVE 3.17, 95% confidence interval (CI): 1.15-8.76: = 0.026; RR for AVA per 0.1 cm 1.28, 95% CI: 1.03-1.55: = 0.024; RR for GFR per 1 ml/min 0.96: 95% CI: 0.94-0.99: = 0.007; RR for NT-proBNP per 1000 pg/ml 1.07: 95% CI: 1.01-1.17: = 0.033; RR for RVSP per 1 mm Hg 1.07: 95% CI 1.02-1.16: = 0.011).

Conclusions: Transapical TAVI in high-risk patients provides good hemodynamic results with acceptable outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8039915PMC
http://dx.doi.org/10.5114/aic.2021.104771DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
patients severe
12
transcatheter aortic
8
valve implantation
8
severe aortic
8
clinical outcomes
8
12-month mortality
8
107 95%
8
patients
6
aortic
5

Similar Publications

Heyde syndrome is a triad of aortic stenosis (AS), gastrointestinal (GI) bleeding from angiodysplasia, and acquired von Willebrand disease (vWD). It is hypothesized that stenotic aortic valves cleave von Willebrand factor (vWF) multimers, predisposing patients to bleeding from GI angiodysplasias. This hypothesis is supported by the observation that aortic valve replacement often leads to the resolution of GI bleeding.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) is a well-established treatment for severe aortic stenosis, especially in patients over 75 or those at high surgical risk. While these prosthetic valves have a lower thrombogenic profile than mechanical heart valves, leaflet thrombosis in transcatheter aortic valves (TAV) occurs in an estimated 5%-40% of cases. Most TAV thromboses are subclinical and can be detected via cardiac computed tomography (CCT), which reveals hypo-attenuating leaflet thickening and reduced leaflet motion in asymptomatic patients without elevated transprosthetic gradients on echocardiography.

View Article and Find Full Text PDF

Introduction: The objective of this study is to determine if cardiac damage based on hospital discharge codes is associated with in-hospital outcomes in patients with aortic stenosis (AS).

Methods: We conducted a retrospective cohort study of hospital admissions between 2016 and 2021 with a diagnosis of AS in the National Inpatient Sample (NIS). The cardiac damage stages 0-4 were determined based on hospital discharge codes.

View Article and Find Full Text PDF

A case of enoxaparin-induced bullous hemorrhagic dermatosis is reported. A 69-year-old male with past medical history including chronic atrial fibrillation and a re-do aortic valve replacement, anticoagulated on warfarin, received an enoxaparin bridge for a molar extraction. On day 7 after restarting enoxaparin post-procedure at a therapeutic dose of 90 mg every 12 hours, the patient noticed multiple small, dark, raised lesions on his forearm and ankle.

View Article and Find Full Text PDF

Background: .Endoscopic mitral valve repair has progressively been adopted as the standard approach for treating isolated mitral regurgitation across numerous renowned cardiac surgery centers worldwide. Our innovative method for mitral valve exposure has been previously described.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!