Purpose: To describe the outcomes of a combined technique (Cyclo Mix) in uncontrolled glaucoma cases.
Materials And Methods: Retrospective study. The Supra 810 nm subliminal laser (Quantel Medical, Cournon d'Auvergne, France) was used. A combined technique was performed using the subliminal mode (Subcyclo) in one hemifield (power of 2,000 mW, a duty cycle of 35%, and 80-150 seconds), and the continuous wave mode (Thermo Cyclo) on the other hemifield (power of 1,000 mW, exposure time of 2 seconds per spot). The primary endpoint was the probability of surgical failure. Mean intraocular pressure (IOP) change, best-corrected visual acuity (BCVA), number of glaucoma eye drops, and complications at 6 months postoperatively were secondary outcomes.
Results: Twenty-three eyes from 13 patients were included. Mean age was 61.4 ± 16.7 (range: 18-78 years), and 69% were female, with a baseline IOP of 20.3 ± 5.9 (range: 13-38 mm Hg). The cumulative probability of failure was 18 and 22% on days 90 and 180, respectively. Mean IOP reduction was -25.6 ± 20.9% at 6 months. The number of glaucoma eye drops was reduced to 1.2 ± 1 ( = 0.0024) at 6 months. No statistically significant change in the mean BCVA compared with baseline at 6 months was found ( = 0.84), and no severe complications were reported.
Conclusion: Cyclo Mix seems to be a safe therapy that effectively reduces the IOP and glaucoma medications in eyes with uncontrolled open-angle glaucoma for up to 6 months.
How To Cite This Article: Waldo L-G, Julio H-Q, Jennifer C-V, Combined Technique for the Application of Micropulse Cyclophotocoagulation in Patients with Uncontrolled Glaucoma: Cyclo Mix. J Curr Glaucoma Pract 2020;14(3):93-97.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8028033 | PMC |
http://dx.doi.org/10.5005/jp-journals-10078-1289 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!