Intra- and inter-observer reliability of implant positioning evaluation on a CT-based three-dimensional postoperative matching system for total knee arthroplasty.

BMC Musculoskelet Disord

Department of Orthopaedic Surgery, Graduate School of Medicine, Development of Orthopaedic Surgery, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, Japan.

Published: April 2021

Background: The evaluation of postoperative total knee arthroplasty (TKA) alignment mainly relies on measurement data obtained from plain radiographs. The aim of this retrospective observational study was to document the intra- and inter-observer reliability in assessment of TKA component positioning after surgery using a three-dimensional (3D) computed tomography (CT) image matching system.

Methods: Fourteen knees from 14 patients who received primary TKA were included, and images were analyzed by blinded readers not associated with the surgeries. The examiner digitized the reference points according to defined landmarks, and the designated size component was superimposed to the 3D reconstructed CT model for measurement. In addition to the evaluation of implant position against the coronal and sagittal lower limb mechanical axes that were defined based on bony landmarks, implant position against axes connecting implant-based reference points that are easier to indicate was evaluated.

Results: The overall intra- and inter-observer reliabilities determined by the intraclass correlation coefficients (ICC) of the implant alignment measurement for both femoral and tibial components were good (ICC > 0.60), except in the direction of femoral flexion and extension, for both mechanical and implant-based axes. The difference between implant alignment measurements according to the traditional mechanical axis and the implant-based axis ranged between means of 0.08 and 1.70 and were statistically significantly different.

Conclusions: The postoperative evaluation of implant position in the coronal and sagittal planes using 3D-CT image matching is reliable and has good reproducibility except for the sagittal alignment assessment of the femoral component. The measured implant position according to the traditional mechanical axis and the implant-based axis were slightly but significantly different.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8053298PMC
http://dx.doi.org/10.1186/s12891-021-04228-2DOI Listing

Publication Analysis

Top Keywords

implant position
16
intra- inter-observer
12
inter-observer reliability
8
total knee
8
knee arthroplasty
8
image matching
8
reference points
8
evaluation implant
8
position coronal
8
coronal sagittal
8

Similar Publications

Post mortem cadaveric and imaging mapping analysis of the influence of cochlear implants on cMRI assessment regarding implant positioning and artifact formation.

Eur Arch Otorhinolaryngol

December 2024

Department of Otorhinolaryngology - Head and Neck Surgery, Medical Center, Faculty of Medicine, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.

Objectives: In times of an aging society and considering the escalating health economic costs, the indications for imaging, particularly magnetic resonance imaging (MRI), must be carefully considered and strictly adhered to. This cadaver study aims to examine the influence of cochlear implant (CI) on the assessment of intracranial structures, artifact formation, and size in cranial MRI (cMRI). Furthermore, it seeks to evaluate the potential limitations in the interpretability and diagnostic value of cMRI in CI patients.

View Article and Find Full Text PDF

Purpose: To evaluate the outcomes of scleral-fixated intraocular lenses (IOLs) implanted using either Yamane technique or Gore-Tex suture fixation, in comparison to intracapsular lens fixation, and to assess the efficacy of various lens formulas in achieving predicted refractive targets.

Patients And Methods: This study included 45 eyes from 44 patients with scleral-fixated IOLs, comprising 37 Yamane eyes and 8 Gore-Tex eyes. Preoperative refractive predictions from various formulae were compared with final postoperative refraction.

View Article and Find Full Text PDF

Pyrocardan® implant interposition in the trapeziometacarpal joint: outcomes at a minimum 10 years' follow-up.

Hand Surg Rehabil

December 2024

Institut de la Main Nantes Atlantique, Boulevard Charles-Gautier, 44800 Saint-Herblain, France.

Objective: We present long-term results for the Pyrocardan®, a pyrocarbon trapeziometacarpal interposition implant used for the treatment of osteoarthritis of the thumb.

Methods: Between March 2009 and May 2013, 199 arthroplasties were performed in a single hand center, in 184 patients by 6 hand surgeons. 107 implants were followed up for a mean 137 months (range, 120 to 168 months).

View Article and Find Full Text PDF

PreVISE: an efficient virtual reality system for SEEG surgical planning.

Virtual Real

December 2024

Department of Computer Science and Software Engineering, Concordia University, Montreal, Québec Canada.

Epilepsy is a neurological disorder characterized by recurring seizures that can cause a wide range of symptoms. Stereo-electroencephalography (SEEG) is a diagnostic procedure where multiple electrodes are stereotactically implanted within predefined brain regions to identify the seizure onset zone, which needs to be surgically removed or disconnected to achieve remission of focal epilepsy. This procedure is complex and challenging due to two main reasons.

View Article and Find Full Text PDF

Introduction: Salvage arthroplasty for failed proximal femoral fracture fixation is a complex procedure. This involves the removal of the primary failed or broken implant followed by a hip joint replacement procedure. The complications and technical difficulties associated with these surgeries are often difficult to anticipate.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!