A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of Endothelial Shear Stress on Absorption Process of Resorbable Magnesium Scaffold: A BIOSOLVE-II Substudy. | LitMetric

Background/purpose: Local hemodynamic forces such as endothelial shear stress (ESS) may have an influence on appropriate neointimal healing, vessel remodeling, and struts' absorption process following second-generation drug-eluting resorbable magnesium scaffold (RMS, Magmaris, Biotronik AG, Buelach, Switzerland) placement. The aim of this study was to investigate the impact of ESS assessed by optical coherence tomography (OCT)-based computational fluid dynamic (CFD) simulations on absorption process and coronary lumen dimension after Magmaris implantation.

Methods And Results: A total of 22 patients who were enrolled in the BIOSOLVE-II trial and underwent serial OCT assessment immediately after Magmaris implantation and at 6- and 12-month follow-up were included. We evaluated qualitative OCT findings frame by frame, and CFD simulations were performed to calculate the ESS at 3-dimensional (3D) reconstructed arteries. For quantitative calculation, the average ESS within each 1-mm section was classified into three groups: low (<1.0 Pa), intermediate (1.0-2.5 Pa), or high (>2.5 Pa). A significant difference of percentage remnants of scaffold was observed among the 3 groups at 12-month follow-up (P = 0.001) but not at 6-month follow-up. Low-ESS segment at baseline resulted in a greater lumen change of -1.857 ± 1.902 mm at 1 year compared to -1.277 ± 1.562 mm in the intermediate-ESS segment (P = 0.017) and - 0.709 ± 1.213 mm in the high-ESS segment (P = 0.001).

Conclusion: After Magmaris implantation, the presence of higher ESS might be associated with slower strut absorption process but less luminal loss.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.carrev.2021.04.003DOI Listing

Publication Analysis

Top Keywords

absorption process
16
endothelial shear
8
shear stress
8
resorbable magnesium
8
magnesium scaffold
8
cfd simulations
8
magmaris implantation
8
12-month follow-up
8
ess
5
impact endothelial
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!