[Perioprocedural mortality after ICD implantation].

Herz

Klinik für Kardiologie, Evangelisches Klinikum Bethel, Bielefeld, Deutschland.

Published: December 2021

Background: Implantable cardioverter defibrillators (ICD) represent an established treatment in preventing sudden cardiac death in patients with indications for primary or secondary prophylaxis. As for all complex surgical procedures there remains a risk for the occurrence of complications including death also for ICD implantation. The aim of the present study was to analyze the procedure-related mortality in patients after ICD implantation using the data from the obligatory quality assurance program in North-Rhine/Westphalia.

Methods: Data of all 18,625 patients from the quality assurance datasets who underwent ICD implantation in the years 2010-2012 were analyzed.

Results: During the in-hospital stay 118 patients (0.6%) died after ICD implantation. Patients > 80 years old had a higher mortality (1.9% vs. 0.5% in patients < 80 years old, p < 0.001) as well as women (0.95% vs. 0.54% in men, p = 0.004) and patients with higher New York Heart Association (NYHA) class (0.3% for NYHA II, 0.7% for NYHA III, 3.4% for NYHA IV, p < 0.001 for all comparisons). The presence of diabetes mellitus (23% of the collective) did not influence the perioperative mortality, whereas renal failure requiring dialysis showed a significantly increased mortality (p < 0.001 compared to patients with creatinine ≤ 1.5 mg/dl and p = 0.002 for patients with creatinine > 1.5 mg/dl not requiring dialysis). Patients with indications for ICD secondary prophylaxis had a significantly higher mortality (1.2% vs. 0.4%, p < 0.001), which increased from 0.6% to 3.7% (p < 0.001) with the occurrence of complications.

Conclusion: The procedure-related mortality after ICD implantation is increased in patients over 80 years of age, higher NYHA class, patients requiring dialysis, in secondary prevention indications and after the occurrence of perioperative complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8642318PMC
http://dx.doi.org/10.1007/s00059-021-05033-2DOI Listing

Publication Analysis

Top Keywords

icd implantation
16
quality assurance
8
icd
6
[perioprocedural mortality
4
mortality icd
4
icd implantation]
4
implantation] background
4
background implantable
4
implantable cardioverter
4
cardioverter defibrillators
4

Similar Publications

Background: The implantable cardioverter-defibrillator (ICD) remains the cornerstone in the prevention of sudden cardiac death. Cost-effectiveness depends on survival after implantation. In Belgium there are unexplained major differences in 3-year mortality after ICD implantation.

View Article and Find Full Text PDF

Can ICD Electrograms Help Ventricular Tachycardia Ablation?: Results From the Multicenter Randomized AIDEG-VTA Trial.

J Am Coll Cardiol

November 2024

Electrophysiology Laboratory and Arrhythmia Unit, Centro Integral de Enfermedades Cardiovasculares, Hospital Monteprincipe, Grupo HM Hospitales, Madrid, Spain. Electronic address:

Background: The results of ablation of sustained monomorphic ventricular tachycardia (SMVT) are suboptimal. For many patients with implantable cardioverter-defibrillators (ICDs), ICD electrograms (ICD-EGs) provide the only available information on SMVT. ICD-EGs have the ability to distinguish morphologically distinct SMVT and can be used for pace mapping.

View Article and Find Full Text PDF

Sudden cardiac death (SCD) remains a major global health concern and represents one of the most common causes of mortality due to cardiovascular diseases. The wearable cardioverter-defibrillator (WCD) is an innovative, non-invasive medical device designed to provide continuous heart monitoring and immediate defibrillation in patients at risk for SCD. The study aimed to assess the efficacy of WCD usage in patients awaiting decision on therapy with implantable cardioverter-defibrillators (ICDs).

View Article and Find Full Text PDF

Cardiac implantable electronic devices and their integrated thoracic impedance sensors have been used to detect sleep apnea for over a decade now. Despite their usage in daily clinical practice, there are only limited data on their diagnostic accuracy. AIRLESS and UPGRADE were prospective investigator-driven trials meant to validate the AP scan (Boston Scientific, Marlborough, MA, USA) in heart failure cohorts.

View Article and Find Full Text PDF

PEAR1 Promotes Myoblast Proliferation Through Notch Signaling Pathway.

Biology (Basel)

December 2024

Department of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China.

PEAR1, also known as platelet endothelial aggregation receptor 1, is known to play a crucial role in the migration and differentiation of muscle satellite cells (MuSCs). However, its specific effects on skeletal muscle development and regeneration require further exploration. In this study, the expression of PEAR1; the proliferation marker proteins of Pax7, CCNB1, and PCNA; and the key molecules of N1-ICD, N2-ICD, and Hes1 were all increased gradually during the process of C2C12 cell proliferation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!