A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Kinematics of a Novel Canine Cervical Fusion System. | LitMetric

Kinematics of a Novel Canine Cervical Fusion System.

Vet Comp Orthop Traumatol

Department of Veterinary Medicine, University of Cambridge, Cambridge, United Kingdom.

Published: July 2021

Objective:  The aim of this study was to determine the biomechanical behaviour of a novel distraction-fusion system, consisting of an intervertebral distraction screw, pedicle locking screws and connecting rods, in the canine caudal cervical spine.

Study Design:  Biomechanical study in cadaveric canine cervicothoracic (C3-T3) spines ( = 6). Cadaveric spines were harvested, stripped of musculature, mounted on a four-point bending jig, and tested using non-destructive four-point bending loads in extension (0-100 N), flexion (0-60 N) and lateral bending (0-40 N). Angular displacement was recorded from reflective optical trackers rigidly secured to C5, C6 and C7. Data for primary and coupled motions were collected from intact spines and following surgical stabilization (after ventral annulotomy and nucleotomy) with the new implant system.

Results:  As compared with the intact spine, instrumentation significantly reduced motion at the operated level (C5-C6) with a concomitant non-significant increase at the adjacent level (C6-C7).

Conclusion:  The combination of a locking pedicle screw-rod system and intervertebral spacer provides an alternative solution for surgical distraction-stabilization in the canine caudal cervical spine and supports the feasibility of using this new implant system in the management of disc-associated cervical spondylomyelopathy in dogs. The increase in motion at C6-C7 may suggest the potential for adjacent level effects and clinical trials should be designed to address this.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0041-1725016DOI Listing

Publication Analysis

Top Keywords

canine caudal
8
caudal cervical
8
four-point bending
8
adjacent level
8
kinematics novel
4
canine
4
novel canine
4
cervical
4
canine cervical
4
cervical fusion
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!