A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Investigating reverse osmosis membrane fouling and scaling by membrane autopsy of a bench scale device. | LitMetric

In response to the escalating world water demand and aiming to promote equal opportunities, reverse osmosis desalination has been widely implemented. Desalination is however constantly subjected to fouling and scaling which increase the cost of desalination by increasing the differential pressure of the membrane and reducing the permeate flux. A bench-scale desalination equipment has been used in this research to investigate the mitigation of fouling and scaling. This study involved the performance of membrane autopsy for fouling characterisation with special attention to flux decline due to sulphate precipitation and biofouling. Visual inspection, scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDS), Fourier transform infrared spectroscopy (FTIR) and microbiology tests (API) were performed. Results obtained showed the presence of diatoms, pseudomonas and polysaccharides as the main foulants causing biofouling. Analysis revealed sulphate deposits as well as aluminium, calcium and silica as the main elements contributing to inorganic scaling. Findings pointed out that the pre-treatment system of the small-scale reverse osmosis water treatment was inefficient and that selection of pre-treatment chemicals should be based on its compatibility with the membrane structure. The importance of characterisation for the verification of fouling mechanisms is emphasised.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09593330.2021.1918262DOI Listing

Publication Analysis

Top Keywords

reverse osmosis
12
fouling scaling
12
membrane autopsy
8
membrane
5
fouling
5
investigating reverse
4
osmosis membrane
4
membrane fouling
4
scaling
4
scaling membrane
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!