A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Noninvasive monitoring of uterine electrical activity among patients with obesity: a new external monitoring device. | LitMetric

Noninvasive monitoring of uterine electrical activity among patients with obesity: a new external monitoring device.

Am J Obstet Gynecol MFM

Department of Obstetrics & Gynecology and Women's Health, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, NY (Drs Moni, Kirshenbaum, Comfort, Kuba, Wolfe, and Bernstein).

Published: July 2021

Background: Tocodynamometry is a common, noninvasive tool used to measure contraction frequency; however, its utility is often limited in patients with obesity. An intrauterine pressure catheter provides a more accurate measurement of uterine contractions but requires ruptured membranes, limiting its utility during early latent labor. Electrical uterine myography has shown promise as a noninvasive contraction monitor with efficacy similar to that of the intrauterine pressure catheter; however, its efficacy has not been widely studied in the obese population.

Objective: This study aimed to validate the accuracy of electrical uterine myography by comparing it with tocodynamometry and intrauterine pressure catheters among laboring patients with obesity.

Study Design: This was a prospective observational study from February 2017 to April 2018 of patients with obesity, aged 18 years or older, who were admitted to the labor unit with viable singleton pregnancies and no contraindications for electromyography. Patients were monitored simultaneously with electrical myography and tocodynamometry or intrauterine catheter for more than 30 minutes. Two blinded obstetricians reviewed the tracings. The outcomes of interest were continuous and interpretable tracing, number of contractions, and timing and duration of contractions, interpreted as point estimates and associated 95% confidence intervals.

Results: A total of 110 patients were enrolled (65 tocodynamometry, 55 intrauterine catheter). Electrical myography was significantly more interpretable during a 30-minute tracing (P=.001) and detected 39% more contractions than tocodynamometry (P<.0001; 95% confidence interval, 23%-57%), whereas there was no difference in the interpretability of tracings or number of contractions between electrical myography and an intrauterine catheter (P=.16; 95% confidence interval, -0.19 to 1.19). Patients who underwent simultaneous monitoring preferred the electrical myography device over tocodynamometry.

Conclusion: Electrical uterine myography is superior to tocodynamometry in the detection of intrapartum uterine contraction monitoring and comparable with internal contraction monitoring.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajogmf.2021.100375DOI Listing

Publication Analysis

Top Keywords

patients obesity
12
intrauterine pressure
12
tocodynamometry intrauterine
12
pressure catheter
8
electrical uterine
8
uterine myography
8
electrical myography
8
intrauterine catheter
8
patients
6
electrical
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!