Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10335261 | PMC |
http://dx.doi.org/10.1308/rcsann.2020.7116 | DOI Listing |
Eur Spine J
January 2025
Center for Musculoskeletal Surgery, Charité- Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany.
Purpose: Although idiopathic scoliosis is a common three-dimensional deformity, there is a lack of studies evaluating the associations between the aortic-vertebral distance (AVD) and spinal deformities in all planes. The study therefore aimed to evaluate how the coronal and sagittal curvature, vertebral rotation and aortic-vertebral angle (AVA) affect the AVD in idiopathic scoliosis.
Methods: The AVD, AVA, vertebral rotation and curve angles were measured on preoperative magnetic resonance imaging and radiographs in 46 patients who underwent posterior spinal fusion with pedicle screw instrumentation for idiopathic scoliosis Lenke types 1 and 2.
Comput Biol Med
January 2025
Department of Biomedical Engineering, Faculty of Science and Engineering, Swansea University, Swansea, United Kingdom; Zienkiewicz Institute for Modelling Data and AI, Swansea University, Swansea, United Kingdom. Electronic address:
Most cell types are mechanosensitive, their activities such as differentiation, proliferation and apoptosis, can be influenced by the mechanical environment through mechanical stimulation. In three dimensional (3D) mechanobiological in vitro studies, the porous structure of scaffold controls the local mechanical environment that applied to cells. Many previous studies have focused on the topological design of homogeneous scaffold struts.
View Article and Find Full Text PDFEur J Surg Oncol
January 2025
Colorectal Unit, General & Digestive Surgery Department, Hospital Universitario Son Espases, Palma de Mallorca, Spain; Instituto de Investigación Sanitaria Illes Balears (IdISBa), Spain.
Background: This study investigates the effectiveness of a three-dimensional reconstruction mathematical model (3D-IPR) for preoperative planning in locally advanced colon cancer (LACC) with threatened surgical margins. The objective was to evaluate the utility of a 3D-IPR surgical planner tool in cases of LACC with threatened surgical margins. Additionally, the study aims to compare the diagnostic accuracy of the 3D-IPR model against conventional CT scans in determining the infiltration of neighboring structures.
View Article and Find Full Text PDFVet Surg
January 2025
Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada.
Objective: To evaluate the accuracy of ventral slot creation in canine cadavers with a three-dimensional (3D)-printed drill guide compared to the freehand technique.
Study Design: Ex vivo study.
Sample Population: Eight canine cadavers (23.
J Med Imaging Radiat Oncol
January 2025
Department of Radiation Oncology, Townsville University Hospital, Townsville, Queensland, Australia.
Introduction: Prostate motion during external beam radiotherapy (EBRT) is common and typically managed using fiducial markers and cone beam CT (CBCT) scans for inter-fractional motion correction. However, real-time intra-fractional motion management is less commonly implemented. This study evaluated the extent of intra-fractional prostate motion using transperineal ultrasound (TPUS) and examined the impact of treatment time on prostate motion.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!