Analysis of isomeric mixtures is a significant analytical challenge. In the forensic field, for example, over 1000 new psychoactive substances (NPSs), comprising of many closely related and often isomeric varieties, entered the drugs-of-abuse market within the last decade. Unambiguous identification of the isomeric form requires advanced spectroscopic techniques, such as GC-Vacuum Ultraviolet Spectroscopy (GC-VUV). The continuous development of NPSs makes the appearance of a novel compound in case samples a realistic scenario. While several analytical solutions have been presented recently to confidently distinguish NPS isomers, the presence of multiple isomers in a single drug sample is typically not considered. Due to their structural similarities it is possible that a novel NPS coelutes with a known isomer and thus remains undetected. This study investigates the capabilities of VUV spectral deconvolution for peak detection and identification in incompletely resolved drug mixtures. To mimic worst case scenarios, severe coelution was deliberately induced at elevated GC temperatures. The deconvolution software was nevertheless able to correctly detect both substances, even in case of near-identical VUV spectra at almost full coelution. As a next step, spectra were subsequently removed from the reference library to simulate the scenario in which a novel substance was encountered for the first time in forensic case work. However, also in this situation the deconvolution software still detected the coelution. This work shows that a VUV library match score below 0.998 may serve as a warning that a novel substance may be present in a street sample.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jchromb.2021.122675 | DOI Listing |
Anal Chem
January 2025
Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-41061, United States.
Glow discharge optical emission spectrometry (GDOES) allows fast and simultaneous multielemental analysis directly from solids and depth profiling down to the nanometer scale, which is critical for thin-film (TF) characterization. Nevertheless, operating conditions for the best limits of detection (LODs) are compromised in lieu of the best sputtering crater shapes for depth resolution. In addition, the fast transient signals from ultra-TFs do not permit the optimal sampling statistics of bulk analysis such that LODs are further compromised.
View Article and Find Full Text PDFAnal Bioanal Chem
January 2025
Department of Plant and Environmental Science, University of Copenhagen, Thorvaldsensvej 40, DK-1871, Frederiksberg, Denmark.
Liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS) is commonly used for identification of compounds in complex samples due to the high chromatographic and mass spectral resolution provided. In subsequent data processing workflows, it is imperative to preserve this resolution to fully exploit the data. "Region of interest" (ROI) algorithms were introduced as a better alternative to equidistant binning for compressing HRMS data because they better preserve the mass spectral resolution.
View Article and Find Full Text PDFJ Immunother Cancer
January 2025
Providence Portland Medical Center, Portland, Oregon, USA.
Objectives: Multiplex immunohistochemistry and immunofluorescence (mIHC/IF) are emerging technologies that can be used to help define complex immunophenotypes in tissue, quantify immune cell subsets, and assess the spatial arrangement of marker expression. mIHC/IF assays require concerted efforts to optimize and validate the multiplex staining protocols prior to their application on slides. The best practice guidelines for staining and validation of mIHC/IF assays across platforms were previously published by this task force.
View Article and Find Full Text PDFSci Rep
January 2025
Hannover Centre for Optical Technologies (HOT), Leibniz University Hannover, Hannover, Germany.
Hyperspectral imaging (HSI) systems acquire images with spectral information over a wide range of wavelengths but are often affected by chromatic and other optical aberrations that degrade image quality. Deconvolution algorithms can improve the spatial resolution of HSI systems, yet retrieving the point spread function (PSF) is a crucial and challenging step. To address this challenge, we have developed a method for PSF estimation in HSI systems based on computed wavefronts.
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
January 2025
Mass Spectrometry Data Center, Biomolecular Measurement Division, National Institute of Standards and Technology (NIST), Gaithersburg, Maryland, 20899, United States.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!