Background And Objective: Chronic Obstructive Pulmonary Disease (COPD) causes substantial morbidity and mortality across the globe. Diagnosis of COPD requires post-bronchodilator FEV1/FVC <0.70 as per GOLD Guidelines. FVC maneuver requires a minimum of 6 seconds of forceful expiration with no flow for 1 second for an accepted effort, which lacks any fixed cut-off point. This leads to discomfort, especially in advanced COPD and old aged population. We conducted this study to find the utility of FEV1/FEV6 as a surrogate for FEV1/FVC, the correlation between the two ratios, and the fixed cut-off value of FEV1/FEV6 for COPD diagnosis.
Methods: This was a prospective, cross-sectional study approved by the institutional ethics committee conducted from January 2017 to November 2018. Consented patients above 18 years suspected of COPD underwent Spirometry as per ATS guidelines. FEV1, FEV6, FEV1/FEV6 and FEV1/FVC ratios were recorded from the best acceptable maneuver.
Results: Out of 560 screened patients, 122 diagnosed as COPD. The correlation coefficient between the post-bronchodilator FEV1/FVC ratio and FEV1/FEV6 ratio was 0.972 (p < 0.01). The relationship between the post-bronchodilator FEV1/FVC ratio and FEV1/FEV6 ratio (linear regression analysis) was found out as: FEV1/FVC = -1.845 + 1.009(FEV1/FEV6). Using this formula, the post-bronchodilator FEV1/FEV6 value of 71.845 was obtained corresponding to the post-bronchodilator FEV1/FVC value of 70.00.
Conclusion: We found a positive correlation coefficient (r = 0.972, p < 0.001) between the FEV1/FEV6 and FEV1/FVC ratios and the cut off value of 71.845 (p < 0.01) for the post-bronchodilator FEV1/FEV6 ratio for the diagnosis of COPD. Thus FEV1/FEV6 should be used as a surrogate for FEV1/FVC for the diagnosis of COPD.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijtb.2020.09.002 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!