Development of hybrid spectrofluorimetric method for simultaneous determination of Valsartan and Sacubitril in LCZ696 tablets.

Spectrochim Acta A Mol Biomol Spectrosc

Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Pharos University in Alexandria, Alexandria, Egypt.

Published: July 2021

A hybrid Spectrofluorimetric method was developed for the simultaneous determination of binary mixtures, without prior separation steps. It coupled synchronous spectrofluorimetry with derivative ratio mathematical treatment. The method was applied successfully to quantify a new model binary mixture consisting of Valsartan (VAL) and Sacubitril (SAC). This mixture was recently approved by FDA as LCZ696. It added a great value in reducing morbidity and mortality in resistant heart failure (HF) patients. First derivative ratio synchronous fluorescence was measured at 258-295 (peak-to-peak) and 204 nm for VAL and SAC, respectively. ICH guidelines were fulfilled for the method validation. VAL and SAC showed linear responses in the range of 60-200 and 20-200 ng mL, respectively. The proposed method was compared, in details, with the reported ones. Its high accuracy, selectivity, simplicity and affordable cost recommend method application in large-scale routine analysis of LCZ696 tablets. Moreover, reliable application of this new integrated spectrofluorimetric method suggests expansion of its application for various therapeutic combinations and different matrices.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2021.119748DOI Listing

Publication Analysis

Top Keywords

spectrofluorimetric method
12
hybrid spectrofluorimetric
8
simultaneous determination
8
lcz696 tablets
8
derivative ratio
8
val sac
8
method
7
development hybrid
4
method simultaneous
4
determination valsartan
4

Similar Publications

Two versatile yet simple methods, colorimetric and spectrofluorimetric, were utilized for the quantitation of nonchromophore neomycin using silver nanoparticles modified with fluorescein. Fluorescein was excited at 485 nm (emission at 515 nm); when it is deposited on the surface of silver nanoparticles, its fluorescence intensity at 515 nm is quenched. Neomycin restores the fluorescence level at 515 nm by displacing fluorescein from nanoparticle binding sites.

View Article and Find Full Text PDF

Highly sensitive spectrofluorimetric methods were developed for the quantitative estimation of formoterol fumarate dihydrate (FFD) and fluticasone propionate (FP) in both authentic raw materials and marketed dosage forms using a micellar-enhanced spectrofluorimetric approach. The proposed methods are based on the determination of FP in the presence of FFD using the first derivative emission spectrofluorimetry. The peak amplitude of the emission spectra of the formed micellar fluorescence was measured at 465 nm after excitation at 236 nm (λ max of FP).

View Article and Find Full Text PDF

Aims: Gastrointestinal stromal tumors (GISTs) account for about 80% of the mesenchymal tumors of the GI tract. About 5000-6000 patients are diagnosed in the United States (US) alone, and up to 14.5 cases per million discovered in Europe annually.

View Article and Find Full Text PDF

Carbon quantum dots (CQDs) are a recently developed class of fluorescent nanoparticles made from carbon. Co-doping with heteroatoms such as nitrogen and sulfur improved the properties and generated a high quantum yield. In the proposed study, we utilized a simple, cost-effective, single-stage hydrothermal approach to produce extreme photoluminescence co-doped, nitrogen and sulfur, CQDs (N,S-CODs).

View Article and Find Full Text PDF

An efficient probe (E)-2-(benzo[d]thiazol-2-yl)-3-(9-ethyl-9 H-carbazol-3-yl)acrylonitrile (CZ-BTZ) for selective fluorescence "turn-on" response with cyanide (CN) ion sensor was developed by simple Knoevenagel condensation of 9-ethyl-9 H carbazole-3-carbaldehyde with 2-(benzo[d]thiazol-2-yl) acetonitrile. The sensing ability of probe CZ-BTZ was tested with different inorganic anions through spectrophotometric and spectrofluorimetric methods. The UV-vis and fluorescence spectral studies show the formation of a new adduct between CZ-BTZ and CN by appearing with a new absorbance band at 350 nm and "turn-on" fluorescence at 535 nm in CHCN: HO (8:2, v/v, pH 7.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!