A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of Tracheal Diameter Measurements on Radiograph Versus Computed Tomography at a Tertiary Care Hospital in Pune, Central India. | LitMetric

Background Variations in tracheal diameter with respect to factors like age and gender are one of the major factors affecting the size of the endotracheal tube (ETT) preferred in a patient. It is important to pre-determine this figure because a tube of a larger size predisposes the patient for tracheal mucosal ischemia, while one of a smaller size may not ensure adequate oxygen saturation in the patient. Purpose We undertook this study to assess the accuracy of radiograph versus computed tomography (CT) and comment on whether a CT should be carried out mandatorily in all patients where intubation is needed. Materials and methods The study was undertaken at Dr DY Patil Medical College, Hospital, and Research Center, a tertiary care institute in Pune, India. A total of 217 patients in whom both chest radiograph and chest CT were performed were enrolled in the study and measurements were performed at suitable landmarks which correspond to the position of endotracheal tubes. Results The males had a mean age of 44.2 years and females of 41.7 years. The mean X-ray transverse diameter was 15.4 ± 3.2 (SD) mm, mean CT axial transverse diameter was 15.3 ± 3.4 (SD) mm, mean CT sagittal diameter was 14.8 ± 3.7 (SD) mm, and the mean CT coronal diameter was 15.2 ± 3.5(SD)mm. Conclusions There was a significant difference in mean X-ray transverse diameter (Low kV), CT axial transverse diameter, CT sagittal diameter, and CT coronal diameter between males and females. Mean values were significantly higher in males as compared to females. There was a significant difference in tracheal diameters for different age groups, irrespective of the modality. Bland-Altman analysis revealed no significant difference between chest radiograph and CT for tracheal diameter measurement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8024437PMC
http://dx.doi.org/10.7759/cureus.13755DOI Listing

Publication Analysis

Top Keywords

transverse diameter
16
tracheal diameter
12
diameter
11
radiograph versus
8
versus computed
8
computed tomography
8
tertiary care
8
chest radiograph
8
x-ray transverse
8
axial transverse
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!