A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the Sysmex UF-4000i urine analyzer as a screening test to rule out urinary tract infection and reduce urine cultures. | LitMetric

Evaluation of the Sysmex UF-4000i urine analyzer as a screening test to rule out urinary tract infection and reduce urine cultures.

Ann Biol Clin (Paris)

Bacteriology-Virology and Hospital Hygiene Laboratory, University Hospital Centre Ibn Rochd of Casablanca, Morocco, Department of Microbiology, Faculty of Medicine and Pharmacy, Hassan II University of Casablanca, Morocco.

Published: April 2021

Introduction: Urinary tract infection (UTI) diagnosis by urine culture is time- and labor- consuming. In the Ibn Rochd microbiology laboratory, up to 70% of urine culture samples yield no growth or insignificant growth.

Objective: To evaluate the new generation of Sysmex UF-4000i fluorescence flow cytometry analyzer with a blue semiconducting laser as a method to rule out negative urine samples for UTI, in comparison of urine culture.

Material And Methods: Flow cytometry and microbiological analysis were performed on 502 urine samples included in the study. We used ROC analysis to determine cutoff points at which optimal sensitivity and specificity are achieved for clinical use.

Results: Our results showed that bacteria count at a cut-off of 100/μL, and/or the leucocytes count ≥45/μL are the optimal indicator for positive culture results. At these cut off, bacteria sensitivity (SE), specificity (SP), Positive predictive value (PPV) and negative predictive value (NPV) were 97,3%, 95%, 87,8% and 98,8% respectively. For leucocytes, SE, SP, PPV and NPV were 99,1%, 95,8%, 88,6% and 99,7% respectively.

Discussion And Conclusion: The bacterial and leucocytes counts generated by UF-4000i analysis may be useful in our context as a rapid screening to exclude UTI by reducing about 70% of urines cultures and then workload. Nevertheless, further validation is needed for different patient groups especially with urological disease or immunocompromised patients.

Download full-text PDF

Source
http://dx.doi.org/10.1684/abc.2021.1634DOI Listing

Publication Analysis

Top Keywords

sysmex uf-4000i
8
urinary tract
8
tract infection
8
urine culture
8
flow cytometry
8
urine samples
8
sensitivity specificity
8
urine
7
evaluation sysmex
4
uf-4000i urine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!