Statement Of Problem: Maxillary bone resorption after multiple extractions can jeopardize the success of an immediate denture, but whether bone volume preservation techniques are effective is unclear.

Purpose: The purpose of this randomized controlled trial was to evaluate the efficacy of socket grafting with a xenogenic bone substitute in participants receiving maxillary immediate removable complete dentures in terms of bone volume preservation (height and width of the bone ridge).

Material And Methods: The study was a single-blinded, randomized controlled clinical trial with 2 balanced parallel arms. Thirty-six participants who had Kennedy Class I edentulous posterior areas bilaterally for at least 3 months and required maxillary immediate removable complete dentures were enrolled. Duplicates of the removable complete denture were made and converted into radiographic and surgical guides. Participants allocated to the test group received deproteinized bovine bone mineral blended with 10% porcine collagen (DBBM-C) in the extraction sockets, and participants in the control group received no grafting material. With a radiographic guide in place, cone beam computed tomography scans were made 10 days after tooth extraction, when the immediate removable complete denture was delivered (D10, baseline), after 3 months (D90), and after 1 year (D365). The scans were superimposed, and measurements were made on the cross-sectional plane of each extraction site. The influence of various prognosis factors associated with bone volume preservation, including the location of tooth extraction, smoking habits, periodontal disease, and operator team, were analyzed.

Results: Of 36 participants, 3 were lost to follow-up. The mean ±standard deviation loss of height of the buccal crest was 1.2 ±1.8 mm in the control group and 0.3 ±1.2 mm in the test group after 3 months of healing (P<.001) and 2.1 ±2.0 mm in the control group and 0.7 ±1.4 mm in the test group after 1 year of follow-up (P<.001). Mean ±standard deviation horizontal ridge width change was 1.3 ±1.4 mm in the control group and 0.5 ±0.8 mm in the test group after 3 months (P<.001) and 2.2 ±1.4 mm in the control group and 0.9 ±1.1 mm in the test group after 1 year of follow-up (P<.001). None of the other prognostic factors had a significant effect at either time period.

Conclusions: Grafting DBBM-C into the extraction socket after removing anterior teeth for immediate removable denture therapy resulted in significantly less vertical buccal crest and horizontal ridge resorption as compared with spontaneous socket healing after 1 year of follow-up. This procedure may be useful for preserving bone, especially when a fixed implant-supported prosthesis is planned.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2021.02.013DOI Listing

Publication Analysis

Top Keywords

removable complete
16
maxillary removable
12
randomized controlled
12
bone volume
12
volume preservation
12
bone
8
bone substitute
8
controlled trial
8
complete dentures
8
complete denture
8

Similar Publications

Objective: To determine the prevalence of dentition defects and the need for orthopedic treatment among the population of the regions of Mongolia.

Materials And Methods: The study involved 444 residents over the age of 18 living in the Khangai region of Mongolia. After a written agreement to participate in the study, an oral examination was performed and the examination data were marked on the map.

View Article and Find Full Text PDF
Article Synopsis
  • The study focused on rehabilitating maxillary single denture cases using two types of implant-retained attachments: telescopic and ball-and-socket, to see which provided better patient satisfaction.
  • It involved 18 completely edentulous patients aged 45-60, where each received a maxillary single denture with different attachment systems, and their satisfaction was assessed immediately after and three months later.
  • Results indicated that patients with telescopic attachments reported greater improvements in comfort, chewing, and overall satisfaction, while those with ball-and-socket attachments only noted better appearance, highlighting the advantages of telescopic systems.
View Article and Find Full Text PDF

The 'roller coaster effect' in premolar extraction cases: clear aligners vs. straight-wire appliance.

Eur J Orthod

December 2024

Department of Orthodontics, State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China.

Objectives: This study aimed to quantitatively investigate the intractable 'roller coaster effect' (RCE) that occurs in premolar extraction cases treated with clear aligner therapy (CAT) or straight-wire appliance (SWA).

Methods: Protrusion cases treated with extraction of bilateral first premolars were included. Pre- and post-treatment cephalograms were obtained to measure the bending angle of occlusal plane (BAOP), namely the occlusal intersection angle between the anterior occlusal plane (AOP) and posterior occlusal plane (POP).

View Article and Find Full Text PDF

Background: Globally, there is growing concern regarding mouth sores, occlusion, cost, ridge resorption, and retention, in the delivery of removable complete dentures fabrication services brought about by the aging of the population and poor oral healthcare. The therapy for edentulous patients can be realized through the use of conventional removable complete dentures, implant-supported prostheses, and computer-aided design/computer-aided manufacturing (CAD/CAM). In Uganda, the therapy for edentulous patients has predominantly been realized through the use of conventional removable complete dentures.

View Article and Find Full Text PDF

Objectives: This study aimed to compare the clinical effectiveness and cost-efficiency of conventional and digital prosthodontic protocols, with a specific focus on milled and 3D-printed digital removable complete dentures.

Methods: This retrospective clinical study was conducted at the Removable Prosthodontics Department of the University of Siena. 60 patients were divided into two groups: 30 received conventional complete dentures, while the remaining 30 received digital complete dentures (15 milled and 15 3D-printed).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!