Purpose: Explore the feasibility of adopting failure modes and effects analysis (FMEA) for risk assessment of a high volume clinical service at a UK radiotherapy center. Compare hypothetical failure modes to locally reported incidents.
Method: An FMEA for a lung radiotherapy service was conducted at a hospital that treats ~ 350 lung cancer patients annually with radical radiotherapy. A multidisciplinary team of seven people was identified including a nominated facilitator. A process map was agreed and failure modes identified and scored independently, final failure modes and scores were then agreed at a face-to-face meeting. Risk stratification methods were explored and staff effort recorded. Radiation incidents related to lung radiotherapy reported locally in a 2-year period were analyzed to determine their relation to the identified failure modes. The final FMEA was therefore a combination of prospective evaluation and retrospective analysis from an incident learning system.
Results: Thirty-six failure modes were identified for the pre-existing clinical service. The top failure modes varied according to the ranking method chosen. The process required 30 h of combined staff time. Over the 2-year period chosen, 38 voluntarily reported incidents were identified as relating to lung radiotherapy. Of these, 13 were not predicted by the identified failure modes, with six relating to delays in the process, three issues with appointment times, one communication error, two instances of a failure to image, and one technical fault deemed unpredictable by the manufacturer. Four additional failure modes were added to the FMEA following the incident analysis.
Conclusion: FMEA can be effectively applied to an established high volume service as a risk assessment method. Facilitation by an individual familiar with the FMEA process can reduce resource requirement. Prospective evaluation of risks should be combined with an incident reporting and learning system to produce a more comprehensive analysis of risk.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8130239 | PMC |
http://dx.doi.org/10.1002/acm2.13238 | DOI Listing |
J Funct Biomater
December 2024
Department of Endodontics, Faculty of Dentistry, Gazi University, 06490 Ankara, Türkiye.
Bond strength between repair and restorative materials is crucial for endodontic success. This study assessed the effects of the following final irrigation solutions on the bond strength of mineral trioxide aggregate (MTA) to a bulk-fill composite: (1) 17% Ethylenediamine tetraacetic acid (EDTA); (2) 2% Chlorhexidine (CHX); (3) 0.2% chitosan; (4) 0.
View Article and Find Full Text PDFJ Funct Biomater
November 2024
King Abdullah International Medical Research Center, Riyadh 11481, Saudi Arabia.
The aim of the study is to assess the impact of mechanical surface treatments on the shear bond strength (SBS) of orthodontic brackets bonded to three-dimensional (3D) printed and milled CAD/CAM provisional materials. Sixty cylindrical samples were fabricated for each provisional material. Samples were treated with one of the following surface treatments: aluminum oxide airborne particle abrasion, diamond bur rotary instrument roughening, and phosphoric acid etching (control).
View Article and Find Full Text PDFHeliyon
December 2024
School of Civil and Hydraulic Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China.
Basalt, which is a geological medium used for engineering construction in Southwest China, contains defect structures at various scales. In particular, the widespread presence of mesoscale hidden joints significantly affects the mechanical properties of basalt and the stability of engineering structures. However, research in this specific subject has been limited.
View Article and Find Full Text PDFHeliyon
December 2024
Department of Advanced General Dentistry, Faculty of Dentistry, Mahidol University, Bangkok, 10400, Thailand.
Objective: The purpose of this study was to examine the effect of several antiseptic mouthwashes on the dentin microtensile bond strength of self-etch adhesive, considering the influence of rinsing with water.
Methods: Forty flat dentin surfaces were produced by sectioning sound extracted third molars. They were randomly divided into four main groups: (1) artificial saliva (control); (2) 1 % hydrogen peroxide; (3) 0.
Adv Sci (Weinh)
December 2024
State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, P. R. China.
MicroRNA (miRNA)-based therapy holds significant potential; however, its structural limitations pose a challenge to the full exploitation of its biomedical functionality. Framework nucleic acids are promising owing to their transportability, biocompatibility, and functional editability. MiRNA-125 is embedded into a nucleic acid framework to create an enzyme-responsive nanoparachute (NP), enhancing the miRNA loading capacity while preserving the attributes of small-scale framework nucleic acids and circumventing the uncertainty related to RNA exposure in conventional loading methods.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!