Background: This study evaluated the feasibility and efficacy of a laparoscopic absorbable fixation device (Securestrap) in total laparoscopic gastropexy in dogs susceptible to gastric dilatation-volvulus (GDV) compared to laparoscopic gastropexy performed with a barbed suture. We hypothesised that both techniques provide suitable gastropexy.

Methods: The gastropexy was performed by straps (TLG-SS group, n = 6) or with a barbed suture (TLG-Vloc group, n = 6). The total surgery time, gastropexy time, the number of straps used and suture bites were recorded. Clinical and ultrasound investigations were performed during follow-up.

Results: The total surgery time was 30 minutes in the TLG-SS, while it was 46.66 minutes in the TLG-Vloc. In the TLG-SS group, gastropexy time was 13 minutes, while 36.3 minutes in the TLG-Vloc. The number of straps employed in TLG-SS was 9, while seven bites were employed in TLG-Vloc. Linear regression analysis of gastropexy time versus the number of procedures was highly correlated (r = 0.84) in the TLG-SS. Complications, clinical and ultrasound findings did not differ between the two techniques at 90 days post-surgery.

Conclusion: TLG-SS laparoscopic technique can be employed safely and effectively in less time and is associated with a relatively short learning curve, which could encourage the widespread use of prophylactic laparoscopic gastropexy.

Download full-text PDF

Source
http://dx.doi.org/10.1002/vetr.113DOI Listing

Publication Analysis

Top Keywords

laparoscopic gastropexy
16
barbed suture
12
gastropexy time
12
total laparoscopic
8
gastropexy
8
fixation device
8
gastropexy performed
8
tlg-ss group
8
total surgery
8
surgery time
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!