Background: This study compared the incidence of loss of reduction (LOR) between metacarpal fractures fixed with screws alone and those fixed with plates and screws. Secondary aims included identifying patient or fracture characteristics associated with increased risk of LOR.
Methods: We retrospectively reviewed 138 metacarpal fractures in 106 patients treated with open reduction internal fixation with screws (60 fractures) or plates and screws (78 fractures) with a mean radiographic follow-up of 50 days for evidence of LOR. We compared the incidence of LOR between the screw and plate groups using a χ test. We performed logistic regression analysis to determine whether patient age, sex, metacarpal location (index, long, ring, small), the presence of multiple metacarpal fractures, or fracture pattern were associated with increased incidence of LOR.
Results: Loss of reduction occurred in 19 (13.8%) of 138 fractures, with no statistically significant difference between lag screw (7 of 60, 11.6%) and plate fixation (12 of 78, 15.4%). Neither fracture pattern nor the presence of multiple metacarpal fractures was associated with an increased incidence of LOR, but patients experienced a 7% increase in the risk of LOR for each additional year of age. Loss of reduction occurred most frequently in index metacarpal fractures (4 of 12, 33%), although this did not reach statistical significance.
Conclusions: We found no difference in LOR incidence between lag screw fixation and plate fixation. The overall incidence of LOR was higher in this study than previously reported and increased with increasing patient age.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9806539 | PMC |
http://dx.doi.org/10.1177/15589447211003181 | DOI Listing |
BMC Musculoskelet Disord
December 2024
Department of Orthopedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, Jinshan Branch, Jinshan District Central Hospital, Shanghai, 201500, China.
Background: The lateral locking plate for the proximal humerus is currently the most commonly used surgical procedure for the treatment of elderly proximal humeral comminuted fractures. Previous studies have found that the rate of postoperative complications in patients of proximal humerus fractures with medial column involvement is relatively high. Through biomechanical methods, this study aims to investigate the effectiveness of the conventional lateral locking plate fixation along with the addition of the metacarpal supporting plate on the medial column in the treatment for proximal humeral fractures involving the medial column.
View Article and Find Full Text PDFGeorgian Med News
October 2024
Worthing Hospital, University Hospitals Sussex NHS Foundation Trust, United Kingdom.
Background: Bennett's fracture, a fracture-dislocation of the base of the first metacarpal, poses significant challenges due to the unique biomechanics of the thumb's carpometacarpal (CMC) joint. Effective management is critical to restoring thumb function and preventing long-term complications such as arthritis and instability.
Objective: This article provides a comprehensive overview of Bennett's fracture, including its mechanism of injury, diagnostic considerations, and management strategies, with a focus on conservative and surgical options.
Jt Dis Relat Surg
January 2025
Kulu Devlet Hastanesi, Ortopedi ve Travmatoloji, El Cerrahisi Bölümü, 42777 Kulu, Konya, Türkiye
Objectives: This study aimed to compare the outcomes and conduct a cost analysis between plate screw fixation and conservative treatment.
Patients And Methods: The retrospective study was conducted with 36 patients (32 males, 4 females; mean age: 30.3±13.
Jt Dis Relat Surg
January 2025
Sağlık Bilimleri Üniversitesi Ümraniye Eğitim ve Araştırma Hastanesi Ortopedi ve Travmatoloji Kliniği, 34764 Ümraniye, İstanbul, Türkiye.
Objectives: In this study, we present our extensive case series on hamatometacarpal fracture-dislocations treated with open reduction and internal fixation and share our treatment strategies and outcomes.
Patients And Methods: Between March 2014 and November 2022, a total of 17 male patients (mean age: 28.6±7.
J Hand Surg Glob Online
November 2024
Hand and Microsurgery Unit, Department of Orthopaedics and Traumatology, Faculty of Medicine, Universiti Kebangasaan Malaysia, Kuala Lumpur, Malaysia.
Purpose: Fixation of metacarpal or phalanx bone fractures is usually performed under general anesthesia (GA) or regional anesthesia and with the use of a tourniquet to minimize bleeding. However, the use of tourniquet causes pain and discomfort after surgery. Wide-awake local anesthesia no tourniquet (WALANT) enables the surgery to be performed with the patient fully awake and without a tourniquet, which allows intraoperative assessment of function during surgery.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!