Case Description: Osseointegration is a relatively new technique for prosthetic limb attachment that offers various improvements for patients with amputation and facilitates joint preservation. We present a case of implant loosening during rehabilitation in a patient with transtibial amputation that was successfully managed through a combination of measures, aiming to promote re-osseointegration of the implant.

Objectives: Not much is known about structured management of adverse events after osseointegration. Septic or aseptic loosening is currently regarded as implant failure, prompting removal and possible re-implantation at a later stage. The objective of this case report was to evaluate the feasibility of salvaging a loosened implant.

Study Design: Case report.

Treatment: A novel treatment approach was employed to enable renewed osseointegration of the implant. First, the bone-implant interface was disrupted and renewed through axial rotation and distal repositioning of the implant. Afterwards, extracorporal shockwave therapy and antibiotic treatment were administered. Prosthetic rehabilitation was then started anew. Regular follow-up x-rays and clinical evaluations were conducted, including standardized outcome tests.

Outcomes: These combined measures led to a successful re-osseointegration of the implant. In a 21-month follow-up, the patient regained a stable and secure gait pattern, using his prosthesis every day for 15 hours and scoring above average on standardized outcome measures.

Conclusion: This represents the first report of implant salvage after failed primary osseointegration. As the associated risks of this novel treatment are very low, investigations are warranted to evaluate this approach on a larger scale.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0309364620953985DOI Listing

Publication Analysis

Top Keywords

patient transtibial
8
transtibial amputation
8
novel treatment
8
standardized outcome
8
implant
7
successful salvage
4
salvage re-osseointegration
4
re-osseointegration loosened
4
loosened implant
4
implant patient
4

Similar Publications

Background: Medial meniscus posterior root tears (MMPRTs) significantly contribute to knee dysfunction, leading to abnormal biomechanics and accelerated cartilage degeneration. Arthroscopic transtibial pullout and all-inside repair are two commonly used techniques for treating MMPRTs, each with unique advantages and limitations.

Objective: To compare the clinical and functional outcomes of the transtibial pullout and all-inside repair techniques in the treatment of MMPRTs, with a focus on postoperative recovery, knee function, and complications.

View Article and Find Full Text PDF

This Technical Note describes a surgical approach that combines circumferential fiber augmentation with transtibial pullout repair for the treatment of medial meniscal posterior root tears. To address the challenge of meniscal extrusion and subsequent joint space narrowing that predisposes to osteoarthritis, this technique uses an artificial ligament to add circumferential collagen fiber reinforcement to improve meniscal extrusion. This integrated approach is designed to address the limitations of conventional tibial pullout repairs by potentially providing better results in preventing meniscal extrusion.

View Article and Find Full Text PDF

Evaluating interface pressure in a lower-limb prosthetic socket: Comparison of FEM and experimental measurements on a roll-over simulator.

J Biomech

January 2025

Arts et Métiers Institute of Technology, Université Sorbonne Paris Nord, IBHGC - Institut de Biomécanique Humaine Georges Charpak, HESAM Université, 151 boulevard de l'Hôpital, 75013 Paris, France. Electronic address:

Improper socket fitting in lower-limb prostheses can lead to significant complications, including pain, skin lesions, and pressure ulcers. Current suspension and socket design practices rely predominantly on visual inspection of the residual limb and patient feedback. Monitoring stress distribution at the residual limb/socket interface offers a more objective approach.

View Article and Find Full Text PDF

: Lower extremity amputations (LEAs) represent a significant health problem. The aim of our study was to analyse the type and trends of diabetes-related LEAs in patients hospitalized in one surgical centre in Bucharest between 2018 and 2021. The second aim was to assess the impact of the COVID-19 pandemic on the trends of LEAs.

View Article and Find Full Text PDF

Medial meniscus root tears (MMRTs) are serious injuries that disrupt knee biomechanics, often accelerating cartilage degeneration and osteoarthritis when left untreated. These injuries are increasingly recognized as a major cause of knee pain and functional limitations, particularly among middle-aged and older adults. This systematic review and meta-analysis aimed to evaluate the outcomes of conservative management compared to surgical intervention for MMRT, focusing on pain relief, functional recovery, and the progression of osteoarthritis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!