Accuracy of implant impression techniques with a scannable healing abutment.

J Prosthet Dent

Professor, Department of Prosthodontics, Korea University Guro Hospital, Seoul, Republic of Korea. Electronic address:

Published: October 2022

Statement Of Problem: Scannable healing abutments are a convenient option to facilitate impression making for implant-supported restorations. However, studies evaluating the accuracy of the impression technique with scannable healing abutments are lacking.

Purpose: The purpose of this in vitro study was to evaluate the accuracy of implant impression techniques with scannable healing abutments.

Materials And Methods: A partially edentulous mandibular dentiform model was fabricated with an epoxy resin, and implants were placed in the mandibular right second premolar and first molar areas. A maxillary dentiform model was then fabricated, and both models were mounted on an articulator. Scan data were obtained from the mounted models and set as the reference scans. The experimental models were divided into 4 groups (n=10). The conventional pick-up impression technique and definitive casts were used in group CI. The scan data from the definitive casts were obtained with a 3D model scanner. An intraoral scanner with a digital body scan was used in group DS. Group MS yielded definitive casts with dual-arch impressions with scannable healing abutments. The fabricated definitive casts were mounted and scanned with a 3D cast scanner. Intraoral scanning with scannable healing abutments was used in group IS. In all 4 groups, the interarch relationship in the maximum intercuspal position was obtained by scanning the facial aspect. The center of the implant head was set as a measurement point for linear intra-arch deviations and implant angle deviations. The mesiopalatal cusp tip of the maxillary right first molar was used to calibrate the linear interarch deviations. The data obtained from each group were compared with the data from the reference scan. As the data were not normally distributed, the Kruskal-Wallis test and Bonferroni correction were used for the analysis (α=.05).

Results: Group MS exhibited significantly higher deviations in linear intra-arch and implant angles compared with the other groups (P<.05). No significant difference was found between the groups in linear interarch deviations (P>.05).

Conclusions: The accuracy of intraoral scanning with scannable healing abutments was comparable with that of conventional pick-up impression techniques and digital scans with scan bodies. However, model scanning with scannable healing abutments may not be clinically acceptable for implant impressions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2020.06.042DOI Listing

Publication Analysis

Top Keywords

scannable healing
32
healing abutments
24
definitive casts
16
impression techniques
12
scan data
12
scanning scannable
12
accuracy implant
8
implant impression
8
scannable
8
techniques scannable
8

Similar Publications

Statement Of Problem: The use of a scannable healing abutment is a convenient option for fabricating implant-supported restorations (ISRs) with a digital workflow; however, clinical studies evaluating prosthetic efficacy are lacking.

Purpose: The purpose of this randomized controlled trial was to investigate the prosthetic efficacy of definitive posterior single ISRs fabricated after scanning using a scannable healing abutment-scan peg (SHA-SP) in comparison with a conventional scan body (CSB). The time for data acquisition, quality of proximal and occlusal contacts, and relative occlusal force of ISRs were measured.

View Article and Find Full Text PDF

Accuracy of implant impression techniques with a scannable healing abutment.

J Prosthet Dent

October 2022

Professor, Department of Prosthodontics, Korea University Guro Hospital, Seoul, Republic of Korea. Electronic address:

Statement Of Problem: Scannable healing abutments are a convenient option to facilitate impression making for implant-supported restorations. However, studies evaluating the accuracy of the impression technique with scannable healing abutments are lacking.

Purpose: The purpose of this in vitro study was to evaluate the accuracy of implant impression techniques with scannable healing abutments.

View Article and Find Full Text PDF

Effect of coded healing abutment height and position on the trueness of digital intraoral implant scans.

J Prosthet Dent

March 2020

Associate Professor, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio.

Statement Of Problem: Information regarding the effect of the height and position of a coded healing abutment (CHA) on the trueness of intraoral digital scans is lacking.

Purpose: The purpose of this in vitro study was to investigate the effect of the height and position of a scannable CHA on the trueness (distance and angular deviations) of intraoral digital scans.

Material And Methods: Scannable CHAs (BellaTek Encode Impression system; Zimmer Biomet Dental) were used in 2 different height pairs (3 mm and 8 mm) on 2 implants at mandibular left second and first molar positions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!