This retrospective, single-center study evaluated the patency rate and predictors of restenosis after percutaneous transluminal angioplasty (PTA) for femoropopliteal stenotic lesions using intravascular ultrasound. We assessed 78 de novo femoropopliteal stenotic lesions (64 patients; mean age, 73.6 ± 9.4 years; average lesion length, 59.8 mm) that underwent PTA under intravascular ultrasound guidance. The primary endpoint was 1-year primary patency. The 1-year primary patency rate was 63%. The frequency of insulin use was significantly greater (44% vs. 12%, p = 0.005), and lesions were significantly longer (77.8 mm vs. 49.2 mm, p = 0.047) in the restenosis group than in the non-restenosis group. The pre-intervention reference lumen area and minimum lumen area (MLA) were significantly smaller in the restenosis group (reference lumen area: 19.7 ± 6.7 mm vs. 23.7 ± 7.4 mm, p = 0.017; MLA 3.9 ± 2.8 mm vs. 5.7 ± 3.9 mm, p = 0.026; respectively). The MLA was significantly smaller and the maximum angle of dissection was significantly larger in the restenosis group (MLA 9.3 mm vs. 12.3 mm, p = 0.013; maximum angle of dissection: 104.1° vs. 69.6°, p = 0.003; respectively) among post-intervention parameters. Multivariate analysis revealed that the independent predictors of 1-year restenosis were the large post-intervention maximum angle of dissection and insulin use. Per receiver operating curve analysis, the best cut-off value of the post-intervention maximum angle of dissection that predicted 1-year restenosis was 70.2° (sensitivity 72.4%, specificity 63.3%, area under the curve 0.70, p = 0.004). In conclusion, the 1-year primary patency rate after PTA for relatively short stenotic femoropopliteal lesions was 63%. The large post-intervention maximum angle of dissection, measured using intravascular ultrasound, and insulin use were independent predictors of restenosis after PTA.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00380-021-01845-8 | DOI Listing |
Sci Rep
January 2025
Physics Department, Faculty of Science, Beni-Suef University, Beni-Suef, 62512, Egypt.
This paper presents a novel investigation of a magnetic sensor that employs Fano/Tamm resonance within the photonic band gap of a one-dimensional crystal structure. The design incorporates a thin layer of gold (Au) alongside a periodic arrangement of Tantalum pentoxide ([Formula: see text]) and Cesium iodide ([Formula: see text]) in the configuration [Formula: see text]. We utilized the transfer matrix method in conjunction with the Drude model to analyze the formation of Fano/Tamm states and the permittivity of the metallic layer, respectively.
View Article and Find Full Text PDFAppl Radiat Isot
January 2025
School of Artificial Intelligence, Wenzhou Polytechnic, Wenzhou, 325035, China. Electronic address:
For the purpose of assessing image quality and calculating patient X-ray dosage in radiology, computed tomography (CT), fluoroscopy, mammography, and other fields, it is necessary to have prior knowledge of the X-ray energy spectrum. The main components of an X-ray tube are an electron filament, also known as the cathode, and an anode, which is often made of tungsten or rubidium and angled at a certain angle. At the point where the electrons generated by the cathode and the anode make contact, a spectrum of X-rays with energies spanning from zero to the maximum energy value of the released electrons is created.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Cerrahpasa Faculty of Medicine, Department of Orthopaedics and Traumatology, Istanbul University-Cerrahpasa, Istanbul, Turkey.
Background: The standard approach for addressing intra-articular calcaneal fractures involves open reduction with plate and screw fixation, with ongoing discourse regarding the application of grafts to address bone gaps. The aim of this study is the temporal comparison of the radiological and functional outcomes in patients undergoing surgery for intra-articular calcaneal fractures, with a specific focus on the use of bone grafts.
Methods: Thirty patients, comprising 13 with iliac grafts and 17 without, were enrolled in the study.
Int J Exerc Sci
December 2024
Department of Sport and Health Sciences, Technical University of Munich, Munich, BY, GERMANY.
In weightlifting, quantitative kinematic analysis is essential for evaluating snatch performance. While marker-based (MB) approaches are commonly used, they are impractical for training or competitions. Markerless video-based (VB) systems utilizing deep learning-based pose estimation algorithms could address this issue.
View Article and Find Full Text PDFJ Exp Orthop
January 2025
Department of Orthopaedic Surgery and Trauma University Center of Montpellier, University of Montpellier Montpellier France.
Purpose: Gap-balanced total knee arthroplasty (TKA) technique relies on initial ligament evaluation, particularly in patient-specific implantation using computer-assisted technologies. This cadaveric study aimed to compare the reproducibility and reliability of medial and lateral gap measurements between manual stress testing and dynamic ligament balancer.
Methods: Initial gap acquisitions were assessed from eight cadaveric knees (four specimens) during the same navigated TKA procedure by five differently skilled surgeons (three seniors and two juniors).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!