A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Staple-line reinforcement using barbed sutures in 1008 sleeve gastrectomies. | LitMetric

Staple-line reinforcement using barbed sutures in 1008 sleeve gastrectomies.

Langenbecks Arch Surg

İstanbul Bariatrics, Obesity and Advanced Laparoscopy Center, Hakkı Yeten Cad, Yeşil Çimen Sok, Polat Tower, No:12/407, Şişli, 34394, İstanbul, Turkey.

Published: August 2021

Purpose: Among various staple-line reinforcement methods applied during sleeve gastrectomy (SG), although data on full-thickness-continuous-suturing (FTCS) is nearly nil, it has been considered as potentially harmful. The safety/efficacy profile of FTCS is assessed.

Methods: All consecutive SGs completing 3-month follow-up were studied. Data on peri-operative parameters, complications, and follow-up were prospectively recorded. All reinforcements were completed by FTCS utilizing barbed suture. Super-super obese, secondary SGs, SGs performed in patients with prior anti-reflux surgery, and SGs performed with additional concomitant procedures were evaluated as "technically demanding" SGs. Student's t/chi-square tests were used as appropriate.

Results: Between January 2012 and July 2020, 1008 SGs (941 "primary-standard," 67 "technically demanding") were performed without mortality/venous event. Single leak occurred in a patient with sleeve obstruction (0.1%). Thirteen bleedings, 4 requiring re-surgery (0.4%), and 17 stenoses (1.7%) were encountered. Four stenoses were treated with gastric bypass (1 emergency), 6 by dilatation(s), and one required parenteral nutrition. Six patients with stenosis chose not to have any treatment. No statistically significant difference was observed in postoperative complications between "primary-standard" and "technically demanding" SGs (p > 0.05). The median follow-up was 44 months. The excess weight loss % at 5th year was 80.1%. Suturing added 28.4 ± 6 minutes to the SG, 3 or fewer sutures were used to complete the reinforcement in > 95%. No mishap/complication occurred related to suturing.

Conclusion: FTCS produced excellent result in terms of leakage/hemorrhage with an acceptable stenosis rate at a low cost with half-an-hour increase in the operating time. In contrast to previous allegations, no harm attributable to stitching itself occurred.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8026176PMC
http://dx.doi.org/10.1007/s00423-021-02161-5DOI Listing

Publication Analysis

Top Keywords

"technically demanding"
12
staple-line reinforcement
8
sgs performed
8
demanding" sgs
8
"primary-standard" "technically
8
sgs
7
reinforcement barbed
4
barbed sutures
4
sutures 1008
4
1008 sleeve
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!