A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Skin wetness detection thresholds and wetness magnitude estimations of the human index fingerpad and their modulation by moisture temperature. | LitMetric

Humans often experience wet stimuli using their hands, yet we know little on how sensitive our fingers are to wetness and the mechanisms underlying this sensory function. We therefore aimed to quantify the minimum amount of water required to detect wetness on the human index fingerpad, the wetness detection threshold, and assess its modulation by temperature. Eight blinded participants (24.0 ± 5.2 yr; 23.3 ± 3.5 body mass index) used their index fingerpad to statically touch stimuli varying in volume (0, 10, 20, 30, 40, or 50 mL) and temperature (25, 29, 33, or 37°C). During and after contact, participants rated wetness and thermal sensations using a modified yes/no task and a visual analog scale. The wetness detection threshold at a moisture temperature akin to human skin (33°C) was 24.7 ± 3.48 mL. This threshold shifted depending on moisture temperature ( = 0.746), with cooler temperatures reducing (18.7 ± 3.94 mL at 29°C) and warmer temperatures increasing (27.0 ± 3.04 mL at 37°C) thresholds. When normalized over contact area, the wetness detection threshold at 33°C corresponded to 1.926 × 10 mL·mm [95% confidence interval (CI): 1.873 × 10, 1.979 × 10 mL·mm]. Threshold differences were reflected by magnitude estimation data, which were analyzed using linear regression to show that both volume and moisture temperature can predict magnitude estimations of wetness ( = 0.949;  = 0.179). Our results indicate high sensitivity to wetness in the human index fingerpad, which can be modulated by moisture temperature. These findings are relevant for the design of products with wetness management properties. The perception of wetness is a fundamental sensory experience which underpins many aspects of life, from homeostasis to enjoyable experiences. Although previous research has highlighted the importance of cold sensations in human wetness perception, the maximum sensitivity of our wetness sensing system remains to be established. This research presents a novel methodology, which for the first time, has quantified the high sensitivity of the human index fingerpad to wetness and its modulation by moisture temperature.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8356767PMC
http://dx.doi.org/10.1152/jn.00538.2020DOI Listing

Publication Analysis

Top Keywords

moisture temperature
24
wetness detection
16
human fingerpad
16
wetness
14
detection threshold
12
magnitude estimations
8
modulation moisture
8
temperature
8
wetness human
8
fingerpad wetness
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!