In vitro evaluation of antibacterial efficacy of vancomycin-loaded suture tapes and cerclage wires.

J Mater Sci Mater Med

Department of Orthopaedic Surgery, Julius-Maximilians University Wuerzburg, Koenig-Ludwig-Haus, Brettreichstrasse 11, 97074, Wuerzburg, Germany.

Published: April 2021

Usage of implants containing antibiotic agents has been a common strategy to prevent implant related infections in orthopedic surgery. Unfortunately, most implants with microbial repellent properties are characterized by accessibility limitations during daily clinical practice. Aim of this in vitro study was to investigate whether suture tapes and cerclage wires, which were treated with vancomycin, show a sustainable antibacterial activity. For this purpose, we used 24 stainless steel wire cerclages and 24 ultra-high molecular weight polyethylene and polyester suture tape test bodies. The test bodies were incubated for 30 min. in 100 mg/ml vancomycin solution or equivalent volumes of 0.9% NaCl. After measuring the initial solution uptake of the test bodies, antibacterial efficacy via agar diffusion test with Staphylococcus aureus and vancomycin elution tests were performed 1, 2, 3, and 6 days after incubation. Vancomycin-loaded tapes as well as vancomycin-loaded cerclage wires demonstrated increased bacterial growth inhibition when compared to NaCl-treated controls. Vancomycin-loaded tapes showed an additional twofold and eightfold increase of bacterial growth inhibition compared to vancomycin-loaded wires at day 1 and 2, respectively. Elution tests at day 1 revealed high levels of vancomycin concentration in vancomycin loaded tapes and wires. Additionally, the concentration in vancomycin loaded tapes was 14-fold higher when compared to vancomycin loaded wires. Incubating suture tapes and cerclage wires in vancomycin solution showed a good short-term antibacterial activity compared to controls. Considering the ease of vancomycin application on suture tapes or wires, our method could represent an attractive therapeutic strategy in biofilm prevention in orthopedic surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8024230PMC
http://dx.doi.org/10.1007/s10856-021-06513-xDOI Listing

Publication Analysis

Top Keywords

suture tapes
16
cerclage wires
16
tapes cerclage
12
test bodies
12
vancomycin loaded
12
vancomycin
9
antibacterial efficacy
8
tapes
8
wires
8
orthopedic surgery
8

Similar Publications

This article aims to present a comprehensive technical note detailing our preferred treatment approach for tibial tuberosity avulsion fractures in the adult and elderly populations, particularly in scenarios characterized by low tissue quality and limited bone stock. Existing literature on this fracture type is scarce, with many described techniques relying on optimal bone quality for effective screw fixation of the tibial tuberosity. Various methods for tibial tuberosity avulsion fixation include K-wires, cannulated screws, staples, tension bands, suture anchors, and in select cases, direct transosseous sutures.

View Article and Find Full Text PDF

Patent foramen ovale (PFO) closure using percutaneous devices, such as the Amplatzer occluder, is a common treatment for patients with a history of cryptogenic stroke or transient ischemic attack (TIA). Although generally well-tolerated, some patients may develop adverse reactions to the device materials, particularly in the presence of a nickel allergy. Symptoms can include chest pain, rashes, and migraines, which may necessitate surgical removal of the device.

View Article and Find Full Text PDF

Introduction: According to current clinical practice, a minimum of 7 knots are required to provide secure hold in high-strength sutures. A new technology featuring a suture tape with a salt-infused silicon core has been recently developed, potentially reducing the number of needed knots.

Aims: to (1) assess the influence of number of knots on tape security, (2) evaluate the effect of different ambient conditions on knot security, and (3) compare the biomechanical competence of the novel versus a conventional suture tape.

View Article and Find Full Text PDF

Purpose: This study aims to perform a systematic review to determine whether ultra-high molecular weight polyethylene (UHMWPE) tapes have superior biomechanical properties compared to conventional sutures in posterior meniscal root tear (PMRT) repairs, and whether this translates into superior clinical outcomes.

Methods: The Cochrane Controlled Register of Trials, PubMed and Embase were used to perform a systematic review using the following search terms: (meniscus OR meniscal) AND (root OR posterior horn) AND (suture OR tape OR wire OR cord). Data pertaining to certain biomechanical properties (load to failure, stiffness, displacement during cyclical loading and at failure), meniscal healing and patient-reported outcome measures (PROMs) were extracted.

View Article and Find Full Text PDF

Securing the endotracheal tube is vital for airway patency, especially in oral surgeries; naso-endotracheal intubation is ideal, but improper fixation risks nasal injury or accidental extubation. This technical note unveils the trans-septal mattress suture technique as a novel approach to secure naso-endotracheal tubes, amplifying stability, reducing trauma, and elevating aesthetic outcomes in head and neck surgeries. This study was performed at the Department of Oral and Maxillofacial Surgery at Kalinga Institute of Medical Sciences, Bhubhaneshwar, Khordha, Odisha, India, from December 2022 to March 2024 with due consent taken from all patients.