Background: Breathing pattern disorders are frequently reported in uncontrolled asthma. At present, this is primarily assessed by questionnaires, which are subjective. Objective measures of breathing pattern components may provide additional useful information about asthma control. This study examined whether respiratory timing parameters and thoracoabdominal (TA) motion measures could predict and classify levels of asthma control.

Methods: One hundred twenty-two asthma patients at STEP 2- STEP 5 GINA asthma medication were enrolled. Asthma control was determined by the Asthma Control Questionnaire (ACQ7-item) and patients divided into 'well controlled' or 'uncontrolled' groups. Breathing pattern components (respiratory rate (RR), ratio of inspiration duration to expiration duration (Ti/Te), ratio of ribcage amplitude over abdominal amplitude during expiration phase (RCampe/ABampe), were measured using Structured Light Plethysmography (SLP) in a sitting position for 5-min. Breath-by-breath analysis was performed to extract mean values and within-subject variability (measured by the Coefficient of Variance (CoV%). Binary multiple logistic regression was used to test whether breathing pattern components are predictive of asthma control. A post-hoc analysis determined the discriminant accuracy of any statistically significant predictive model.

Results: Fifty-nine out of 122 asthma patients had an ACQ7-item < 0.75 (well-controlled asthma) with the rest being uncontrolled (n = 63). The absolute mean values of breathing pattern components did not predict asthma control (R = 0.09) with only mean RR being a significant predictor (p < 0.01). The CoV% of the examined breathing components did predict asthma control (R = 0.45) with all predictors having significant odds ratios (p < 0.01). The ROC curve showed that cut-off points > 7.40% for the COV% of the RR, > 21.66% for the CoV% of Ti/Te and > 18.78% for the CoV% of RCampe/ABampe indicated uncontrolled asthma.

Conclusion: The within-subject variability of timing parameters and TA motion can be used to predict asthma control. Higher breathing pattern variability was associated with uncontrolled asthma suggesting that irregular resting breathing can be an indicator of poor asthma control.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8022412PMC
http://dx.doi.org/10.1186/s40733-021-00071-3DOI Listing

Publication Analysis

Top Keywords

asthma control
28
breathing pattern
24
pattern components
16
asthma
13
predict asthma
8
uncontrolled asthma
8
timing parameters
8
asthma patients
8
within-subject variability
8
breathing
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!