Measurements of dynamic surface changes by digital holography for in situ plasma erosion applications.

Rev Sci Instrum

Third Dimension Technologies, Oak Ridge, Tennessee 37830, USA.

Published: March 2021

There are currently few viable diagnostic techniques for in situ measurement of plasma facing component erosion. Digital holography is intended to fill this gap. Progress on the development of single and dual CO laser digital holography diagnostics for in situ plasma facing component erosion is discussed. The dual laser mode's synthetic wavelength allows the measurable range to be expanded by a factor of ∼400 compared to single laser digital holography. This allows the diagnostic to measure surface height changes of up to 4.5 μm in single laser mode and up to 2 mm in dual laser mode. Results include ex situ measurements of plasma eroded targets and also dynamic measurements of nm and μm scale motion of a target mounted on a precision translation stage. Dynamic measurements have successfully been made with the system operating in both single and dual laser modes, from ∼50 nm to ∼4 μm in single laser mode and up to ∼400 μm in dual laser mode (limited only by the stage speed and camera acquisition duration). These results demonstrate the feasibility of using digital holography to characterize plasma facing component erosion dynamically, i.e., during plasma exposure. Results of proof-of-principle in situ digital holographic measurements of targets exposed to an electrothermal arc plasma source are presented.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0040566DOI Listing

Publication Analysis

Top Keywords

digital holography
20
dual laser
20
laser mode
16
plasma facing
12
facing component
12
component erosion
12
single laser
12
situ plasma
8
single dual
8
laser
8

Similar Publications

We recently demonstrated polarisation differential phase contrast microscopy () as a robust, low-cost single-shot implementation of (semi)quantitative phase imaging based on differential phase microscopy. utilises a polarisation-sensitive camera to simultaneously acquire four obliquely transilluminated images from which phase images mapping spatial variation of optical path difference can be calculated. microscopy can be implemented on existing or bespoke microscopes and can utilise radiation at a wide range of visible to near infrared wavelengths and so is straightforward to integrate with fluorescence microscopy.

View Article and Find Full Text PDF

Background And Purpose: Quantitative MRI (qMRI) has been explored for detecting tumor changes during radiation therapy (RT) in head and neck squamous cell cancer (HNSCC). Clinical trials show prolonged survival with PD-1 targeted immune checkpoint inhibition. Hypofractionated radiation regimens are being studied to counteract radioresistant clonogen formation.

View Article and Find Full Text PDF

Traditional numerical reconstruction methods in digital holography (DH) are faced with problems such as inaccurate and time-consuming unwrapping or the need to capture multiple holograms with different diffraction distances. In recent years, deep learning, believed to be a new and effective optimization tool, has been widely used in digital holography. However, most supervised deep learning methods require large-scale paired data, and their preparation is time-consuming and laborious.

View Article and Find Full Text PDF

This paper introduces an interferometer for single-shot areal quantitative phase imaging at two wavelengths simultaneously, suitable for use with low coherence sources. It operates in reflection geometry with on-axis illumination, so that it can be conveniently applied to surface texture measurements. The system consists of two identical 4f systems forming the reference and sample arm.

View Article and Find Full Text PDF

Phase-shifting Fringe projection profilometry (FPP) excels in 3D measurements for many macro-scale applications, but as features-of-interest shrink to the microscopic scale, depth-of-field limitations slow measurements and necessitate mechanical adjustments. To address this, we introduce digital holography (DH) for fringe image capture, enabling numerical refocusing of defocused object regions. Our experiments validate this approach and compare depth measurement noise with other DH and FPP methods.

View Article and Find Full Text PDF