Purpose: To evaluate dosimetric properties of intensity-modulated proton therapy (IMPT) for simulated treatment planning in patients with atrial fibrillation (AF) targeting left atrial-pulmonary vein junction (LA-PVJ), in comparison with volumetric-modulated arc therapy (VMAT) and helical tomotherapy (TOMO).

Methods: Ten thoracic 4D-CT scans with respiratory motion and one with cardiac motion were used for the study. Ten respiratory 4D-CTs were planned with VMAT, TOMO, and IMPT for simulated AF. Targets at the LA-PVJ were defined as wide-area circumferential ablation line. A single fraction of 25 Gy was prescribed to all plans. The interplay effects from cardiac motion were evaluated based on the cardiac 4D-CT scan. Dose-volume histograms (DVHs) of the ITV and normal tissues were compared. Statistical analysis was evaluated via one-way Repeated-Measures ANOVA and Friedman's test with Bonferroni's multiple comparisons test.

Results: The median volume of ITV was 8.72cc. All plans had adequate target coverage (V  ≥ 99%). Compared with VMAT and TOMO, IMPT resulted in significantly lower dose of most normal tissues. For VMAT, TOMO, and IMPT plans, D of the whole heart was 5.52 ± 0.90 Gy, 5.89 ± 0.78 Gy, and 3.01 ± 0.57 Gy (P < 0.001), mean dose of pericardium was 4.74 ± 0.76 Gy, 4.98 ± 0.62 Gy, and 2.59 ± 0.44 Gy (P < 0.001), and D of left circumflex artery (LCX) was 13.96 ± 5.45 Gy, 14.34 ± 5.91 Gy, and 8.43 ± 7.24 Gy (P < 0.001), respectively. However, no significant advantage for one technique over the others was observed when examining the D of esophagus and main bronchi.

Conclusions: IMPT targeting LA-PVJ for patients with AF has high potential to reduce dose to surrounding tissues compared to VMAT or TOMO. Motion mitigation techniques are critical for a particle-therapy approach.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8130224PMC
http://dx.doi.org/10.1002/acm2.13239DOI Listing

Publication Analysis

Top Keywords

vmat tomo
12
tomo impt
12
atrial fibrillation
8
intensity-modulated proton
8
proton therapy
8
impt simulated
8
cardiac motion
8
normal tissues
8
dosimetric feasibility
4
feasibility stereotactic
4

Similar Publications

Article Synopsis
  • This study explored the effectiveness and safety of three advanced stereotactic body radiation therapy (SBRT) techniques for treating pancreatic cancer: CyberKnife (CK), Tomography Radixact (TOMO), and Halcyon volume rotation intensity modulation therapy (VMAT).
  • Sixteen patients were analyzed using different SBRT plans, with a focus on optimization methods and median radiation doses.
  • Results indicated that CK with multi-leaf collimator (CK-MLC) provided the best protection for surrounding organs while effectively targeting the tumor, demonstrating its superior dosimetric properties compared to the other methods.
View Article and Find Full Text PDF

Background: Hippo-avoidance prophylactic cranial irradiation (HA-PCI) requires a hippocampal avoidance zone expanded from hippocampus to ensure dose fall-off and compensate for setup errors. Most studies recommend a 5-mm margin, while it could be optimized to a 2-mm expansion. Here, we showed the details of optimized HA-PCI for limited-stage small cell lung cancer (LS-SCLC).

View Article and Find Full Text PDF

Purpose: Hippocampal-avoidance whole-brain radiotherapy (HA-WBRT) planning can present challenges. This study examines the influence of head tilt angles on the dosimetric characteristics of target and organs at risk (OARs), aiming to identify the optimal tilt angle that yields optimal dosimetric outcomes using tomotherapy (TOMO).

Methods: Eight patients diagnosed with brain metastases underwent CT scans at five tilt angles: [0°, 10°), [10°, 20°), [20°, 30°), [30°, 40°), and [40°, 45°].

View Article and Find Full Text PDF
Article Synopsis
  • * The automated method was benchmarked against traditional Tomotherapy (M-TOMO) and Volumetric Modulated Arc Therapy (A-VMAT), showing significant improvements in target dose distribution and lower radiation exposure to surrounding organs.
  • * A-TOMO not only maintained similar dose uniformity but also achieved faster treatment planning times of about 20 minutes, making it a promising advancement in cervical cancer treatment planning.
View Article and Find Full Text PDF

To explore the relationships between gastrointestinal radiation injuries of pancreatic cancer patients treated with TOMO and dose-volume histogram parameters prospectively. Seventy patients with pancreatic cancer who underwent TOMO were enrolled in this prospective study from February 2015 to May 2020. The clinical and dose-volume histogram parameters of the patients were collected.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!