Previous work showed that the beginning of a sound is more important for the perception of loudness than later parts. When a short silent gap of sufficient duration is inserted into a sound, this primacy effect reoccurs in the second sound part after the gap. The present study investigates whether this temporal weighting occurs independently for different frequency bands. Sounds consisting of two bandpass noises were presented in four different conditions: (1) a simultaneous gap in both bands, (2) a gap in only the lower frequency band, (3) a gap in only the higher frequency band, or (4) no gap. In all conditions, the temporal loudness weights showed a primacy effect at sound onset. For the frequency bands without a gap, the temporal weights decreased gradually across time, regardless of whether the other frequency band did or did not contain a gap. When a frequency band contained a gap, the weight at the onset of this band after the gap was increased. This reoccurrence of the primacy effect following the gap was again largely independent of whether or not the other band contained a gap. Thus, the results indicate that the temporal loudness weights are frequency specific.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8017310PMC
http://dx.doi.org/10.3389/fpsyg.2021.588571DOI Listing

Publication Analysis

Top Keywords

frequency band
16
band gap
16
temporal loudness
12
loudness weights
12
gap
12
frequency
8
weights frequency
8
frequency specific
8
frequency bands
8
bands gap
8

Similar Publications

Deep brain stimulation (DBS) effectively treats motor symptoms of advanced Parkinson's disease (PD), with the globus pallidus interna (GPi) commonly targeted. However, its therapeutic mechanisms remain unclear. We employed optogenetic stimulation in the entopeduncular nucleus (EP), the rat homologue of GPi, in a unilateral 6-OHDA lesioned female Sprague Dawley rat model of PD.

View Article and Find Full Text PDF

Objectives: We assessed the positive predictive value (PPV) of 17 myositis antibodies for having a diagnosis of myositis and other myositis-spectrum conditions (interstitial lung disease (ILD), connective tissue diseases (CTD), malignancy) and evaluated the impact of semiquantitative classification and antibody overlap on the PPVs.

Materials And Methods: We retrospectively identified 1068 individuals ≥18 years who tested positive for ≥1 antibody in the EUROLINE myositis line blot assay or positive for anti-3-hydroxy-3-methylglutaryl-CoA reductase (HMGCR) in an ELISA-based test between 2015 and 2020 in 15 out of the 20 hospital districts in Finland. We extracted clinical diagnoses from the Care Register for Health Care between January 2013 and June 2022.

View Article and Find Full Text PDF

A multi-band high-sensitivity microwave sensor for simultaneous detection of two dielectric materials.

Rev Sci Instrum

January 2025

The State Key Laboratory of Complex Electromagnetic Environment Effects on Electronic and Information System, Luoyang 471004, China.

A multi-band high-sensitivity microwave sensor is reported. The two resonance units are based on complementary square spiral resonators (CSSRs) and produce four measurement bands through parasitic resonances. The four frequency bands are 2.

View Article and Find Full Text PDF

Purpose: This study aims to improve the detection of glutamate (Glu) concentration and T using an enhanced transverse relaxation encoding with narrowband decoupling (TREND) technique.

Methods: A new editing pulse was designed to simultaneously invert both Glu H3 spins (2.12 ppm and 2.

View Article and Find Full Text PDF

This paper introduces an optimal sizing approach for battery energy storage systems (BESS) that integrates frequency regulation via an advanced frequency droop model (AFDM). In addition, based on the AFDM, a new formulation for charging/discharging of the battery with the purpose of system frequency control is presented. The studied MG system that consists of PV units, a diesel generator (DG), a combined heat and power (CHP) unit, a gas boiler, and a BESS is designed to meet the consumers' thermal and electrical load requirements as well as system frequency regulation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!