The stable operation of a turbulent combustor is not completely silent; instead, there is a background of small amplitude aperiodic acoustic fluctuations known as combustion noise. Pressure fluctuations during this state of combustion noise are multifractal due to the presence of multiple temporal scales that contribute to its dynamics. However, existing models are unable to capture the multifractality in the pressure fluctuations. We conjecture an underlying fractional dynamics for the thermoacoustic system and obtain a fractional-order model for pressure fluctuations. The data from this model has remarkable visual similarity to the experimental data and also has a wide multifractal spectrum during the state of combustion noise. Quantitative similarity with the experimental data in terms of the Hurst exponent and the multifractal spectrum is observed during the state of combustion noise. This model is also able to produce pressure fluctuations that are qualitatively similar to the experimental data acquired during intermittency and thermoacoustic instability. Furthermore, we argue that the fractional dynamics vanish as we approach the state of thermoacoustic instability.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0032585DOI Listing

Publication Analysis

Top Keywords

pressure fluctuations
20
combustion noise
16
state combustion
12
experimental data
12
multifractality pressure
8
fractional dynamics
8
similarity experimental
8
multifractal spectrum
8
thermoacoustic instability
8
fluctuations
6

Similar Publications

Joint Analysis of Cardiovascular Control and Shear Wave Elastography to Determine Carotid Plaque Vulnerability.

J Clin Med

January 2025

Operative Unit of Vascular Surgery, IRCCS Policlinico San Donato, 20097 San Donato Milanese, Italy.

: Carotid artery stenosis (CAS) is one of the main causes of stroke, and the vulnerability of plaque has been proved to be a determinant. A joint analysis of shear wave elastography, a radiofrequency echo-based wall tracking technique for arterial stiffness evaluation, and of autonomic and baroreflex function is proposed to noninvasively, preoperatively assess plaque vulnerability in asymptomatic CAS patients scheduled for carotid endarterectomy. : Elastographic markers of arterial stiffness were derived preoperatively in 78 CAS patients (age: 74.

View Article and Find Full Text PDF

The aim of the study was to create a nanofiber insert incorporating Timolol (TIM) and Dorzolamide (DOR), targeting the management of glaucoma. This condition encompasses a variety of chronic, advancing ocular disorders typically associated with elevated intraocular pressure (IOP). The insert was made of Eudragite RL100 (EUD) polymer, a biocompatible material with high bioavailability, using the electrospinning method.

View Article and Find Full Text PDF

Background: Strong primary care (PC) services are the foundation of high-performing health care systems and can support effective responses to public health emergencies. Primary care practitioners (PCPs) and PC services played crucial roles in supporting global health system responses to the COVID-19 pandemic. However, these contributions have come at a cost, impacting on PC services and affecting patient care.

View Article and Find Full Text PDF

Over the last 50 years, contribution of the immune system has been identified in the development of hypertension and renal injury. Both human and experimental animal models of hypertension have demonstrated that innate and adaptive immune cells, along with their cytokines and chemokines, modulate blood pressure fluctuations and end organ renal damage. Numerous cell types of the innate immune system, specifically monocytes, macrophages, and dendritic cells present antigenic peptides to T cells promoting inflammation and the elevation of blood pressure.

View Article and Find Full Text PDF

Data-independent acquisition (DIA) on ion mobility mass spectrometers enables deep proteome coverage and high data completeness in large-scale proteomics studies. For advanced acquisition schemes such as parallel accumulation serial fragmentation-based DIA (diaPASEF) stability of ion mobility (1/K) over time is crucial for consistent data quality. We found that minor changes in environmental air pressure systematically affect the vacuum pressure in the TIMS analyzer, causing ion mobility shifts.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!