High-throughput microflow cytometry has become a focal point of research in recent years. In particular, droplet microflow cytometry (DMFC) enables the analysis of cells reacting to different stimuli in chemical isolation due to each droplet acting as an isolated microreactor. Furthermore, at high flow rates, the droplets allow massive parallelization, further increasing the throughput of droplets. However, this novel methodology poses unique challenges related to commonly used fluorometry and fluorescent microscopy techniques. We review the optical sensor technology and light sources applicable to DMFC, as well as analyze the challenges and advantages of each option, primarily focusing on electronics. An analysis of low-cost and/or sufficiently compact systems that can be incorporated into portable devices is also presented.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8004903PMC
http://dx.doi.org/10.3390/mi12030345DOI Listing

Publication Analysis

Top Keywords

microflow cytometry
12
droplet microflow
8
optical detection
4
detection methods
4
methods high-throughput
4
high-throughput fluorescent
4
fluorescent droplet
4
cytometry high-throughput
4
high-throughput microflow
4
cytometry focal
4

Similar Publications

A Microflow Chip Technique for Monitoring Platelets in Late Pregnancy: A Possible Risk Factor for Thrombosis.

J Blood Med

January 2025

Department of Blood Transfusion of Yong-chuan Hospital, Chongqing Medical University, Chongqing, 402160, People's Republic of China.

Purpose: To study the platelet adhesion and aggregation behaviour of late pregnancy women under arterial shear rate using microfluidic chip technology and evaluate the risk of thrombosis in late pregnancy.

Methods: We included pregnant women who were registered in the obstetrics department of our hospital between January 2021 and October 2022 and underwent regular prenatal examinations. Blood samples were collected at 32-35 weeks of gestation for routine blood tests and progesterone, oestradiol, and platelet aggregation function.

View Article and Find Full Text PDF

An integrated microflow cytometry platform with artificial intelligence capabilities for point-of-care cellular phenotype analysis.

Biosens Bioelectron

March 2025

Department of Biotechnology, National Formosa University, No. 64, Wunhua Rd, Huwei Township, Yunlin County, 63201, Taiwan. Electronic address:

The EZ DEVICE is an integrated fluorescence microflow cytometer designed for automated cell phenotyping and enumeration using artificial intelligence (AI). The platform consists of a laser diode, optical filter, objective lens, CMOS image sensor, and microfluidic chip, enabling automated sample pretreatment, labeling, and detection within a single compact unit. AI algorithms segment and identify objects in images captured by the CMOS sensor at 532 and 586 nm emission wavelengths.

View Article and Find Full Text PDF

Objectives: A microfluidic flow cytometer-based point-of-care (POC) analyzer was validated against an in-laboratory hematology analyzer (Sysmex XN Automated Hematology System). Concordance on a full complete blood cell count (CBC) with 5-part differential, as performed by operators with no prior clinical laboratory experience, was evaluated.

Methods: We prospectively collected 376 venous blood specimens (376) from individuals with self-reported medical conditions and from apparently healthy individuals.

View Article and Find Full Text PDF
Article Synopsis
  • - Myelodysplastic syndromes (MDS) are rare early-stage blood cancers that can progress to leukemia, diagnosed through blood tests, bone marrow biopsies, and genetic analysis.
  • - Traditional flow cytometry is widely used but has limitations in detection sensitivity, speed, and cost, prompting the need for improved methods.
  • - Recent advancements in microflow cytometry, combined with microfluidics, show promise in enhancing the diagnosis of MDS and other blood cancers by offering benefits like portability, faster processing times, and lower operational costs.
View Article and Find Full Text PDF

Miniaturized flow cytometry has significant potential for portable applications, such as cell-based diagnostics and the monitoring of therapeutic cell manufacturing, however, the performance of current techniques is often limited by the inability to resolve spectrally-overlapping fluorescence labels. Here, the study presents a computational hyperspectral microflow cytometer (CHC) that enables accurate discrimination of spectrally-overlapping fluorophores labeling single cells. CHC employs a dispersive optical element and an optimization algorithm to detect the full fluorescence emission spectrum from flowing cells, with a high spectral resolution of ≈3 nm in the range from 450 to 650 nm.

View Article and Find Full Text PDF